EN
Look out for children, pets, open windows, and cleaned
cars during operation.
Clean the machine.
Discard the unwanted material when you complete work.
12
MAINTENANCE
Do not let brake fluids, gasoline, petroleum-based materials
touch the plastic parts. Chemicals can cause damage to the
plastic, and make the plastic unserviceable.
Do not use strong solvents or detergents on the plastic
housing or components.
Remove the battery pack from the machine before
maintenance.
12.1
CLEAN THE MACHINE
The machine must be dry. Humidity can cause risks of
electrical shocks.
Clear the unwanted material out of the air vent with a
vacuum cleaner.
Do not spray the air vent or put the air vent in solvents.
Clean the housing and the plastic components with a
moist and soft cloth.
13
TRANSPORTATION AND
STORAGE
Remove the battery pack from the machine before
tranportation and storage.
13.1
MOVE THE MACHINE
Only hold the machine with the handgrip.
13.2
STORE THE MACHINE
Clean the machine before storage.
Make sure that the motor is not hot when you store the
machine.
Make sure that the machine does not have loose or
damaged parts. If it is necessary, do these steps/
instructions:
Replace the damaged parts.
Tighten the bolts.
Speak to a person of an approved service center.
CAUTION
CAUTION
WARNING
CAUTION
WARNING
English
Store the machine in a dry area.
Make sure that children cannot come near the machine.
14
TROUBLESHOOTING
PROBLEM
The motor does
not start when
you pull the trig-
ger.
The machine does
not start.
The air does not
flow through the
tube when you
start the machine.
15
TECHNICAL DATA
Voltage
Air volume
Air speed
Weight (without
battery pack)
Battery model
Charger model
The recommended ambient temperature range:
Item
Blower storage temperature
range
Blower operation tempera-
ture range
Battery charging temperature
range
Charger operation tempera-
ture range
Battery storage temperature
range
Battery discharging tempera-
ture range
8
POSSIBLE
SOLUTION
CAUSE
Make sure that
The battery pack is
you tighlty install
not installed tight-
the battery pack in
ly.
the machine.
The battery pack is
Charge the battery
out of power.
pack.
The power switch
is defective.
Replace the defec-
The motor is defec-
tive parts by an ap-
tive.
proved service
center.
The PCB board is
defective.
The air inlet or
Remove the block-
tube outlet has a
age.
blockage.
24 V
450 CFM
110 MPH (177 Km/h)
4.41 lbs. (2.0 kg)
BAG709 and other BAG series
CAG801 and other CAG series
Temperature
32°F (0°C) - 113°F (45°C)
32°F (0°C) - 113°F (45°C)
39°F (4°C) - 104°F (40°C)
39°F (4°C) - 104°F (40°C)
32°F (0°C) - 113°F (45°C)
32°F (0°C) - 113°F (45°C)

Publicité

loading

Ce manuel est également adapté pour:

Blg401