SC24
DEFAULT SETTINGS
• DIP 1 and DIP 2 both OFF: Step-by-step with stop
• DIP 3 OFF: Pre-flashing disabled
• DIP 4 OFF: Safety device test disabled
• DIP 5 OFF: Opening photocell disabled
• DIP 6 ON: Automatic closing enabled
• DIP 7 OFF: Deceleration disabled
• DIP 8 OFF: Fast closing disabled
• DIP 9 OFF: Uninfluential
• DIP 10 ON: LEDs powered
2
Closing limit switch
motor stop
TRIMMER ADJUSTMENT
• The trimmers TR1, TR2, TR3, TR4 can be adjusted also during gate movement and hence the effect immediately be
checked.
•
The trimmer TR5 is stored only during the rest phase (gate closed).
Function
Trimmers
TR1
FORCE
TR2
AMP. FORCE
TR3
SLOW
TR4
AMP. SLOW
TR5
PAUSE
DEFAULT SETTINGS
• TRIMMER TR1 TR3 TR5 adjusted to minimum
•
TRIMMER TR2 and TR4 adjusted to maximum
All manuals and user guides at all-guides.com
500 600mm
Limit switch slowing
down in closing
Description
Adjusts the motor FORCE level. The force is increased by turning the trimmer clockwise.
Adjusts the intervention threshold of the anti-crushing function during non-decelerated motion.
When it intervenes the motion is locked and inverted for 2 seconds in order to free the obstacle.
The intervention threshold is increased by turning the trimmer clockwise.
Adjusts the DECELERATION level. Deceleration is decreased by turning the trimmer clockwise
(turning clockwise the gate speed/force is increased).
Adjusts the intervention threshold of the anti-crushing function during slow motion.
When it intervenes the motion is locked and inverted for 2 seconds in order to free the obstacle.
The intervention threshold is increased by turning the trimmer clockwise.
Adjusts the PAUSE TIME from 2 to 215 seconds. The value is increased by turning the
trimmer clockwise.
Opening limit switch
motor stop
Limit switch slowing
down in opening