Télécharger Imprimer la page

GiBiDi SC24 Instructions D'utilisation page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
SC24
ELECTRICAL CONNECTIONS: FASTONS
Position
Signal
1
0 Vac
2
18 Vac
3
24 Vac
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
Signal
1
0 Vac
2
+24 Vac
3
+SK BAT
4
-SK BAT
M1
5
LAMP
6
SPIA
7
COM
8
OPT
9
STOP
10
START
11
PED
M2
12
PHOTO
13
SAFETY
14
COM
15
MOTOR OPEN
16
MOTOR CLOSE
17
+ ACCES
M3
18
+ SAFETY
19
COM
20
FCA
21
FCC
22
GND
M5
23
ANT
PROTECTION FUSES
Position
Value
F1
315 mA
FAST-BLOW
F2
5 A
FAST-BLOW
500 mA
F3
FAST-BLOW
All manuals and user guides at all-guides.com
Description
Transformer 0 Vac connection (black cable).
Transformer 18 Vac connection (orange cable).
Transformer 24 Vac connection (red cable).
Description
0 Vac output to the BATTERY CHARGER BOARD.
24 Vac output to the BATTERY CHARGER BOARD.
Positive connection to the BATTERY CHARGER BOARD.
Negative connection to the BATTERY CHARGER BOARD.
Flashlight output 24V 10W max (slow flashing during opening, off with gate open, fast
flashing during closing); it can also be connected to the battery charger board.
Warning light output 24V 3W max (slow flashing during opening, on fixed with gate
open, fast flashing during closing).
Common INPUTS - OUTPUTS.
Not used.
STOP input (N.C.). If not used, jumper with terminal 14.
START input (N.O.).
PEDESTRIAN input (N.O.).
PHOTOCELL input (N.C.). If not used, jumper with terminal 14.
SAFETY DEVICE input (N.C.). If not used, jumper with terminal 14 and set DIP 4 to OFF.
Common INPUTS - OUTPUTS.
24V motor output - open.
24V motor output - close.
+24 Vdc external accessory power supply (photocells, radio, etc.).
24 Vdc power supply for external safety devices (frame), active only during the
operating cycle; connect the devices on which to run the safety test to this input (also
see DIP 4).
Common INPUTS - OUTPUTS.
Opening limit switch input.
Closing limit switch input.
NTENNA BRAID input.
ANTENNA SIGNAL input.
Description
Type
Protects the ACCESSORY and SAFETY DEVICE power supply.
Protects the control unit at the 24 VAC power supply input.
Protects the flashlight output.
N.B. Do not connect if the board is assembled
on the operator.