4-5
INDOOR AND OUTDOOR CONNECTING WIRE CONNECTION
You can connect indoor/outdoor lead wire without removing the front panel.
1 Open the front panel.
2 Remove two screws holding the cabinet, then remove the cabinet.
3 Remove one screw holding the electrical cover, then remove the cover.
4 Remove one screw holding the cord clamp, then remove the clamp.
5 Pass the indoor/outdoor unit connecting wire and fix the wire to the terminal block.
6 Secure the indoor/outdoor unit connecting wire and the earth wire with the cord clamp.
7 Re-install the fixture and electrical cover securely.
Indoor
terminal block
Cord clamp
Indoor/outdoor unit connecting wire A
Warning:
• Use the indoor/outdoor unit connecting wire that meets the Standards to connect the indoor and
outdoor units and fix the wire to the terminal block securely so that no external force is conveyed to
the connecting section of the terminal block. Incomplete connection or fixing of the wire could result
in a fire.
• Attach the cord clamp securely. If it is attached incorrectly, it could result in a fire or an electric shock
due to dust, water, etc.
Loosen terminal
screw.
15 mm
Lead wire
Terminal block
<Connection details>
Caution:
• Be careful not to make mis-wiring.
• Firmly tighten the terminal screws to prevent them from loosening.
• After tightening, pull the wires lightly to confirm that they do not move.
• If the connecting wire is incorrectly connected to the terminal block, the unit does not operate nor-
mally.
• If an earth is incorrect, it may cause an electric shock.
• Make earth wire a little longer than the others. (more than 55 mm)
All manuals and user guides at all-guides.com
ELECTRICAL COVER
Fixing screw
Never fail to hook the right claw on the VA clamp to
secure indoor/outdoor unit connecting wire A.
Securely push the wire into the terminal block
until no part of its core is appeared.
Indoor terminal block
Earth wire
(green/yellow)
35 mm
Indoor/outdoor unit
connecting wire A
4-core 1.5 mm
2
Outdoor terminal block
4-6
AUTO RESTART FUNCTION
• These models are equipped with an auto restart function. If you do not want to use this function, please
consult the service representative because the setting of the unit needs to be changed.
• When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and
the fan speed are memorized by the indoor electronic control P.C. board. The auto restart function sets to
work the moment the power has restored after power failure, then, the unit will restart automatically. If the unit
is operated in "AUTO" mode before power failure, the operation mode (COOL, DRY or HEAT) is not stored in
the memory. When the main power is turned on, the unit decides the operation mode by the initial room
temperature at restart and starts operation again.
Operation
1 If the main power has been cut, the operation settings remain.
2 When three minutes have passed after power was restored, the unit will restart automatically according to
the memory.
Notes:
• The operation settings are memorized when 10 seconds have passed after the remote controller was oper-
ated.
• If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer
setting is cancelled. As these models are equipped with an auto restart function, the air conditioner starts
operating with timer cancelled at the same time that power is restored.
• If the unit has been off with the remote controller before power failure, the auto restart function does not work
as the power button of the remote controller is off.
• To prevent breaker off due to the rush of starting current, systematize other home appliances not to turn on
at the same time.
5