Test certificate
DVGW
31460000
31464000
31660000
31664000
Fault
Insufficient water
Mixer stiff
Mixer dripping
Set hot water limiter
Instantaneous heater didn't work
with thermostat
6
All manuals and user guides at all-guides.com
P-IX
SVGW
PA-IX
X
9952/ICB
X
PA-IX
X
9953/IB
X
Cause
-Shower filter seal dirty
-Non return valve hasn't moved
back
-Cartridge defective, calcified
-Cartridge defective
-Hot water limiter incorrectly set
-Flow limiter in handshower isn't
removed
-Filters are dirty
-Non return valve hasn't moved
back
English
ACS
X
X
NF
WRAS
X
X
X
X
Remedy
-Clean filter seal between shower
and hose
-Exchange non return valves
-Exchange cartridge
-Exchange cartridge
-Set hot water limiter
-Remove flow limiter
-Clean the filter / exchange filter
-Exchange non return valves
KIWA
X
X