Télécharger Imprimer la page

Xylem FLOJET 02830 Serie Manuel D'installation Et D'utilisation page 3

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
INSTALLATION & OPERATION
City water IN
or draw from tank
prime up to 8 feet
120°F (49°C)
Safe Water
Operating
Temperature
ON/OFF
Valve
34°F (1.1°C)
Flojet Pressure
Regulator
01752-XXXX
(not included)
Make connections
using stepless
or suitable hose
clamps
1. Install the booster and power supply indoors, in an area
protected from splash, spillage, or soiling.
2. Install service valves (not included) before and after the system
as required to create a system bypass loop.
3. Note: For incoming water supply line install a 30 psi (2.1 bar)
Flojet pressure regulator PN#01752-XXXX (not included with
all models). Failure to do so may void warranty.
4. Adjust precharge pressure on accumulator tank to label
specified pressure using air or nitrogen only. Failure to do so
may void warranty.
Warning: Do not use CO
precharge.
5. Connect inlet and outlet fittings to suitably rated hose using
stainless stepless clamps.
6. Turn on incoming water. Plug in the system and open outlet
valves and purge air from the system.
7. Inspect systems and installation for leaks and proper function.
8. Periodically check accumulator pre-charge and re-presurize as
required to proper setting. See system label.
WARRANTY
XYLEM LIMITED WARRANTY WARRANTS THIS PRODUCT TO BE FREE OF DEFECTS AND WORKMANSHIP FOR A PERIOD OF 1 YEAR FROM DATE OF MANUFACTURE. THE
WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF WHATEVER NATURE RELATING
TO THE GOODS PROVIDED HEREUNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
WHICH ARE HEREBY EXPRESSLY DISCLAIMED AND EXCLUDED. EXCEPT AS OTHERWISE PROVIDED BY LAW, BUYER'S EXCLUSIVE REMEDY AND SELLER'S AGGREGATE LIABILITY
FOR BREACH OF ANY OF THE FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT PAID
BY THE BUYER HEREUNDER. IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONSEQUENTIAL,
PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF
BUSINESS, LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION. THIS WARRANTY IS ONLY A REPRESENTATION OF THE COMPLETE LIMITED WARRANTY.
FOR A DETAILED EXPLANATION, PLEASE VISIT US AT www.xylem.com/en-us/support/, CALL OUR OFFICE NUMBER LISTED, OR WRITE A LETTER TO YOUR REGIONAL OFFICE.
RETURN PROCEDURE
Warranty returns are conducted through the place of purchase. Please contact the appropriate entity with a receipt of purchase to verify date.
Accumulator
Tank
for accumulator
2
Pump
and/or non-carb
Filtration
Cautions and Warnings
RISK OF AN ELECTRICAL SHOCK!
Follow all local and electrical and safety codes NEC and
OSHA. Install in a GFI protected outlet for maximum
protection.
Disconnect power before servicing the unit.
For use with water only. Do not pump flammable
liquids. Do not use in a flammable environment.
EXPLOSION HAZARD: Do not use for pumping flamma-
ble liquids with flash point below 100°F (37.8°C). Doing
so may result in explosion which could cause personal
injury, death or property damage.
Caution: Pressurized System; Release pressure from
accumulator tank and system prior to servicing.
Warning: Do not use CO
CO
mixed with water and brass components can create a
2
hazardous chemical reaction.
After any "Water Boil Warning or Water boil Advisory"
is lifted, be sure to completely flush and sanitize your
system. Remove and replace the bladder in the tank or
replace the tank as needed. Test water as necessary to be
sure contaminants are no longer present.
Regulate incoming water pressure to 30 psi (2 bar) max.
Tank must be pre-charged with air to 50-60 psi (3.4-4 bar).
3
Flojet Pressure
Regulator
01752-XXXX
(optional)
Install just prior
to equipment for
pressure control
Water out to
carbonator
(still water)
dispensing
valves
for accumulator precharge.
2
Dispenser

Publicité