TECHNICAL DATA / INSTALLATION SER
B
TECHNICAL DATA
Max gate weight
Max gate surface
Limit switch winding capacity
Nominal functioning torque
Max operating torque
Max lifting force from earth
Max operating force
Pulley revolutions
Pulley diameter
Shaft diameter
EEC Power supply
Motor capacity with load
Power absorbed with load
Capacitor
Functioning cycles
Daily operations suggested
Service
Nominal functioning time
Motor weight
Working Temperature
Protection
*
*
SER 20
Ø 200 / 7,8
SER 22
Ø 220 / 8,6
SER 22S
Ø 220 / 8,6
SER 24
Ø 240 / 9,4
ROLLING GATE CONTROL
The European Standard EN 12604 "Industrial, Commercial and Garage Doors and Gates -
Mechanical Aspects - Requirements", at the point 4.3. "Protection against unintentional and
uncontrolled movements" requires also that*:
a - The vertically operating door leaves shall be balanced so that the door leaf can stop in
any position, or that the out-of-balance state shall not produce, in any case, a static
force at the primary closing edge of the door exceeding 150N (15,3 kg / 33,70 lbs).
Verify it after having manually released the SER operator.
b - If a spring fails, the resulting out-of-balance static force occurring at the primary
closing edge of the roller shutter shall not exceed 200N (20,4 kg / 44,94 lbs), even
when the SER operator is manually released. After this failure, you must intervene on
the door to substitute the broken spring and correct the balance state. Therefore, we
suggest you to fraction the roller shutter weight with an adequate number of springs
(* This is a free interpretation).
WARNING: The EN 12445 standard "Industrial, commercial and garage doors and gates
- safety in use of power operated doors - test methods" at point 4.1.2 "safeguarding
against hazard of being lifted" provides that the rolling gate shall not be able to lift more
than 20 kg / 44 lbs. In order to meet this standard, ALLMATIC suggests to install a control
board with electric power regulation.
6-1624000 REV. 11 DEL 13/12/2022
326 / 12,8
41 / 1,6
**
SER 20
ø 48 / 1,9
SER 22
ø 60 / 2,3
SER 22S
ø 60 / 2,3
SER 24
ø 76 / 2,9
Measurements in mm/inch
22
SER 20
kg/lbs
2
m
N. rotat.
9,5
Nm
150
Nm
110
kg/lbs
150/330
kg/lbs
110/242
rpm
11
mm/in
200/7,8
mm/in
48/1,8
W
A
µF
N.
N.
s
kg/lbs
8,5/18,7
°C
IP
COMMAND TYPE
with manned operation
**
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way.
A: Command button with manned operation (that is, operating as long as activated).
B: Key selector with manned operation.
C: Motor force regulation.
D: Safety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
E: Photoelectric cells (To apply on the whole height of the door up to max 2,5 m as
indicated on EN 12445 point 7.3.2.2).
IN ORDER TO ENSURE A CORRECT FUNCTION ONLY
ALLMATIC'S COMPONENTS MUST BE USED
1 - SER operator
2 - Photoelectric cells (external)
3 - Push-Button
14
SER 22
SER 22 S
220/485
16
8,5
165
200
120
165
160/352
190/418
110/242
150/330
10
220/8,6
60/2,3
230V ~ 50Hz / 120V ~ 60Hz
620 / 450
2,78 / 4,1
20 / 60
7 - 20s/2s
20
30%
330
9,5/20,9
10/22
-10 ÷ +70
30
Parts to install meeting the EN 12453 standard
USE OF THE SHUTTER
Skilled persons
Skilled persons
(out of public
(public area)
area*)
A
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp
SER 24
280/617
24
7,5
290
200
240/528
165/363
9
240/9,4
76/2,9
600 / 500
2,8 / 4,16
20 / 60
14 - 20s/2s
30
630
11/24,2
Unrestricted use
B
-
C and D, or E
C and D, or E
C and D, or E