ATTACH THE SUPPORT
1. Put a thick, protective covering
over cooktop, set-in range
or countertop to protect from
damage or dirt.
2. Determine and clearly mark
with a pencil on the ceiling where
the rangehood will be installed.
.
3. A template (L in FIGURE 6) for
mounting the support is supplied
in the carton with the support.
Use this template to mark holes
for support on the ceiling.
4. Determine and make necessary cuts for the ductwork. The
duct opening is shown on the mounting template (L in FIGURE
6). Install ductwork before mounting the support.
IMPORTANT NOTE: BE CAREFUL WHEN DETERMINING THE
LOCATION FOR THE HOLE IN YOUR CEILING FOR THE DUCT
WORK. THIS HOLE SHOULD NOT BE CENTERED OVER THE
CENTER OF THE COOKING SURFACE AS THE DUCT WORK
THAT RUNS UP INSIDE THE CHIMNEY AND THROUGH THE
CEILING IS NOT IN THE EXACT CENTER OF THE CHIMNEY.
5. Determine the proper location for the Power Supply Cable as
indicated on the template. Use a 1 1/4" Drill Bit to make this hole.
Run the Power Supply Cable. Use caulking to seal around the hole.
DO NOT turn on the power until installation is complete! A
knockout is provided at the top of the UPPER CHIMNEY SUPPORT
(E in FIGURE 7).
6. For ducted installations, place the round DAMPER (A in FIGURE
7) into the exhaust opening of the rangehood and press down.
7. Before attaching the support to the ceiling, you must determine
the desired length of the support structure and adjust the length of
the support by removing the eight screws (indicated in FIGURE
7) with a flat head screwdriver. Once the length of the support is
determined, install and tighten the eight screws.
FIGURE 7
8. Slide the UPPER CHIMNEY COVER (C in FIGURE 1 for
ducted installations - the upper chimney that came with the
rangehood, or G in FIGURE 8 for ductless installations - the
upper chimney that came with the ductless kit) down over the
UPPER CHIMNEY SUPPORT (E in FIGURE 7) until it rests on the
motor box (D in FIGURE 7). Attach the entire support to the ceiling.
Make sure that the support is firmly attached to the ceiling.
Ductless installations require a Ductless Conversion Kit whose
components are pictured in FIGURE 8. Do not use the DAMPER
(A in FIGURE 7) for ductless installations. The LOWER CHIM-
NEY COVER (B in FIGURE 1) should be discarded and replaced
by the new one with the hole from the Ductless Conversion
Kit (F in FIGURE 8). The UPPER CHIMNEY COVER (C in
FIGURE 1) should be discarded and replaced by the shorter
one from the Ductless Conversion Kit (G in FIGURE 8).
FIGURE 6
As indicated in FIGURE 8, place the FLANGE (A) into the
exhaust opening of the rangehood and press down. Fit the
DUCTLESS DIVERTER EXTENSION VERTICAL (B) over the
FLANGE (A) and fit the DUCTLESS DIVERTER (C) over the
EXTENSION (B). Fit the DUCTLESS DIVERTER EXTENSION
HORIZONTAL (D) into the DIVERTER (C).
Remove the cover from the field wiring compartment. DO NOT
turn on the power until installation is complete! Connect
the Power Supply Cable to the rangehood. Attach the White
lead of the power supply to the White lead of the rangehood
with a twist-on type wire connector. Attach the Black lead of the
power supply to the Black lead of the rangehood with a twist-on
type wire connector. Connect the Green (Green and Yellow)
ground wire under the Green grounding screw.
1. The UPPER CHIMNEY
COVER (C in FIGURE 9)
attaches using two screws
provided (G in FIGURE
9). Slide up and attach the
UPPER CHIMNEY COVER.
2. Attach the duct work to the
DAMPER (A in FIGURE 7).
Make sure to seal all joints with
duct tape to prevent leaks.
3. The LOWER CHIMNEY COVER (B in FIGURE 9) rests
on the top of the CANOPY SECTION (A in FIGURE 1)
once it is installed. Install the LOWER CHIMNEY COVER
by sliding it up over the support.
For ductless installations, line up the DUCTLESS DIVERTER
EXTENSION HORIZONTAL (D in FIGURE 8) with the hole
in the LOWER CHIMNEY COVER (F in FIGURE 8) and
snap in the VENT GRID (E in FIGURE 8).
FOR DUCTLESS INSTALLATIONS
FIGURE 8
MAKE THE ELECTRICAL CONNECTION
INSTALLING THE RANGEHOOD
FIGURE 9
Version 3/08 - Page 7