Télécharger Imprimer la page

Heath Zenith 6115 Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

SyMPTOM
Light does not come
on.
Light does not turn
off.
Light comes on
randomly in AUTO
mode.
Light comes on in
the AUTO mode
without motion.
Light does not turn
on in AUTO mode.
Light does not stay
on in AUTO mode.
Light turns on in
daylight in the AUTO
mode.
Light does not come
on in AUTO mode
but works correctly
in the ON and OFF
positions.
All manuals and user guides at all-guides.com
TROUbLEShOOTING
POSSIbLE CAUSE
1. Circuit breaker or fuse is turned off.
2. If the lamp being controlled has an-
other switch, it may be turned off.
3. Bulb is burned out.
4. LIGHT control not set properly.
5. Mode switch is in the OFF position.
6. Poor connection.
7. Switch ground wire is not connected
to house ground.
8. Control may be wired wrong.
1. Mode switch is in the ON position.
2. Motion is still present.
3. Delay set by TIME control has not
expired.
4. Control may be wired wrong.
1. Switch is being triggered by air vent
or other heat source.
2. Control may be wired wrong.
1. Mode switch has been turned off and
back on.
2. There was a momentary power inter-
ruption.
If there is too much light already in the
room, the light may not come on.
1. Motion has stopped in the room.
2. TIME control is set for too short a
delay.
LIGHT control not set properly.
Control is not wired correctly.
1. Turn circuit breaker on.
2. Turn other switch on.
3. Replace light bulb.
4. Turn the LIGHT control clockwise
(see Light Sensitivity Level, page 3).
5. Set switch to AUTO or ON.
6. Verify all wiring connections.
7. Connect switch ground wire to house
ground wire.
8. Verify wiring is correct, see Figure 3.
1. Set switch to AUTO or OFF.
2. Make sure there is no motion during
TIME control period.
3. Set switch TIME control to shorter
time period.
4. Verify wiring is correct, see Figure 3.
1. Determine the source triggering the
switch and alter air flow.
2. Verify wiring is correct, see Figure 3.
1. Control will function normally after
1 minute warm up period.
2. Control will function normally after
1 minute warm up period.
Turn the LIGHT control clockwise (see
Light Sensitivity Level, page 3).
1. Continue movement.
2. Set switch TIME control to longer
time period.
Turn the LIGHT control counter-
clockwise (see Light Sensitivity Level,
page 3).
WARNING: Turn power off at
the fuse or circuit breaker before
re-wiring.
Switch the black and brown sensor
wires and test again. See Figure 3.
4
SOLUTION
598-1372-01