SENSOR PHC LIFTER REPAIR
Protective barrier
L-bracket
screw
Ohmic
contact wire
connector
7. Use a small flat-blade screwdriver to disconnect the black ohmic contact wire from the J1 terminal block (labeled
"Shield").
Note:
When reconnecting the ohmic contact wire, it does not matter which of the two J1 terminals it is connected to.
8. Reverse the order of the steps for reassembly.
Note:
Only finger-tighten the plastic nuts to avoid damage.
To replace the proximity sensor or breakaway assembly
1. To remove the red magnetic breakaway, pull down on it and rotate it at the same time. (It will be easier if the torch is
still attached.)
4
0
Plastic nuts (3)
Caution:
The red magnet is powerful and
can cause injury. Do not catch
fingers or other objects between
the two halves of the magnet.