Télécharger Imprimer la page

Hypertherm 805840 Mode D'emploi page 3

Publicité

Les langues disponibles

Les langues disponibles

SENSOR PHC LIFTER REPAIR
Preparation
Before you remove the lifter from the cutting table, position the carriage approximately at the middle of its travel position
for the best access to internal components.
Remove the upper and lower covers
1. Use a 3 mm allen wrench to remove the 6 screws from the upper cover and then remove the cover.
Lower cover screws (4 mm)
Upper cover screws
(3 mm)
Upper cover
screws (3 mm)
2. Use a 4 mm allen wrench to remove the 4 screws from the lower cover.
3. Slide the lower cover down and off the lifter.
4. Reverse the order of the steps for reassembly.
2
0
Upper cover
Upper cover screws (3 mm)
Lifter interface pin
connector
Lower cover screws (4 mm)
Magnetic coupler
Lower cover
Bracket