Motion Sensor
Entryway Light
Models SL-5610/15
The Heath
®
on up to 60 watts of incandescent light when motion
is detected and then, after a selectable time period,
automatically turns the light off. The built-in photocell
keeps the light off during daylight hours.
This package includes:
globe
(SL-5615)
Entryway Light
Mounting Nut and Stem
• The Entryway Light requires 120-volts AC.
• If you want to use Manual Override, the light must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
© 2007 HeathCo LLC
Get user manuals:
See SafeManuals.com
/Zenith Motion Sensor Entryway Light turns
Sensor
jar
or
(SL-5610)
Mounting Strap and
Grounding Wire
Requirements
Mode:
Test
Auto
Manual
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
2 Screws
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
2 Wire
Manual mode works only with the
Connectors
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
OPERATION
On-Time
Works:
5 Seconds
1, 5, or 10 Min
Until Dawn*
1
TEST
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
OFF then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
Day Night
x
x
x
x
/
minutes for
2
ON-TIME
10 5 1 TEST
1 Second
595-5498-09

Publicité

loading

Sommaire des Matières pour Heath Zenith SL-5610

  • Page 1 TEST ON-TIME Put the ON-TIME switch on the bottom of the sensor in the TEST position. Models SL-5610/15 10 5 1 TEST The Heath /Zenith Motion Sensor Entryway Light turns ® AUTO on up to 60 watts of incandescent light when motion...
  • Page 2 INSTALLATION ❒ Caulk the back edge of the light and mounting surface with silicone weather sealant. For best performance, mount the fixture about 7ft (2.1 ❒ Install a 60 Watt maximum light bulb into the lamp m) above the ground. holder.
  • Page 3 TEST AND ADJUSTMENT The detector is less sensitive to motion directly towards it and more sensitive to across motion. ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 minute calibration period Motion Motion before it will detect motion. When first turned on, wait 1 minutes.
  • Page 4 TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light will not come 1. Light switch is turned off. Light comes on 1. Entryway Light may be sensing small 2. Light bulb is loose or burned for no apparent animals or automobile traffic (re-aim out.
  • Page 5 Ponga el interruptor de tiempo (ON- TIME), al fondo del detector, en la posición de prueba (TEST). 10 5 1 TEST Modelos SL-5610/15 Para AUTOMATICO: La luz del pasillo de entrada detectora de movimiento ON-TIME Ponga el interruptor de tiempo...
  • Page 6 INSTALACION ❒ Calafatee la placa trasera y la superficie de montaje con un sellador de silicón contra la intem- Para un mejor funcionamiento, instale el aparato a casi perie. 2,1 m del suelo. ❒ Coloque una bombilla de 60 Vatios de luz, máximo, en el portalámparas.
  • Page 7 PRUEBA Y AJUSTE El detector es menos sensitivo al movimiento que se dirige directamente hacia él. ❒ Prenda el cortacircuitos y el interruptor. NOTA: El detector tiene un período de 1 minutos Movimiento Movimiento de calibración antes de detectar movimiento. Cuando lo prenda por primera vez, espere 1 minutos.
  • Page 8 GUIA DE INvESTIGACION DE AvERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se enci- l u z 1. El interruptor de luz está apaga- 1. El control de luz puede estar detectan- ende. p r e n d e s i n do animales pequeños o el trásito de ninguna razón...
  • Page 9 * Revient au mode automatique au lever du soleil. Note: Après mise en circuit, attendre enfiron minute pour que l’étalonnage du circuit soit complété. ESSAI Modèles SL-5610/15 ON-TIME Amener en position d’essai (TEST) l’interrupteur de temps en circuit (ON- Le luminaire d’entrée à détecteur de mouvement Heath ®...
  • Page 10 INSTALLATION ❒ Calfeutrer le rebord arrière du luminaire et la surface de montage avec un scellant silicone résistant aux intempéries. Pour un rendement optimal, montez le luminaire à environ 2,1 m au-dessus du sol. ❒ Installer une ampoule d’au plus 60 W dans la douille du luminaire.
  • Page 11 ESSAIS ET RÉGLAGES Le détecteur est moins sensible au mouvement dans sa direction. ❒ Mettre en circuit le disjoncteur et l’interrupteur d’éclairage. Motion Motion NOTE: Le capteur passe par une période d’étalonnage de 1 minute avant de pouvoir détecter le mouvement.
  • Page 12 GUIDE DE DÉPANNAGE SYMPTÔME CAUSE POSSIBLE SYMPTÔME CAUSE POSSIBLE L ’ é c l a i r a g e 1. L’interrupteur d’éclairage est en L’éclairage 1. Le luminaire d’entrée pourrait s’allume pas. s’allume sans position hors circuit. détecter de petits animaux ou des 2.

Ce manuel est également adapté pour:

Sl-5615