The Heath
/Zenith Motion Sensor Entryway Light turns
®
on up to 60 watts of incandescent light when motion
is detected and then, after a selectable time period,
automatically turns the light off. The built-in photocell
keeps the light off during daylight hours.
This package includes:
Sensor
globe
or
(SL-5615)
Entryway Light
Mounting Nut and Stem
Requirements
• The Entryway Light requires 120-volts AC.
• If you want to use Manual Override, the light must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
© 2009 HeathCo LLC
2 Screws
jar
(SL-5610)
2 Wire
Connectors
Mounting Strap and
Grounding Wire
OPERATION
Mode:
On-Time
Test
5 Seconds
Auto
1, 5, or 10 Min
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the
1, 5, or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Works:
Day Night
x
/
minutes for
1
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second
OFF then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
595-5498-10
x
x
x

Publicité

loading

Sommaire des Matières pour Heath Zenith SL-5610

  • Page 1 TEST ON-TIME Put the ON-TIME switch on the bottom of the sensor in the TEST position. 10 5 1 TEST Models SL-5610/15 AUTO The Heath /Zenith Motion Sensor Entryway Light turns ® ON-TIME Put the ON-TIME switch in the on up to 60 watts of incandescent light when motion 1, 5, or 10 minute position.
  • Page 2 INSTALLATION ❒ Caulk the back edge of the light and mounting surface with silicone weather sealant. For best performance, mount the fixture about 7ft (2.1 ❒ Install a 60 Watt maximum light bulb into the lamp m) above the ground. holder.
  • Page 3 ❒ Rotate the sensor base left Avoid aiming the control at: and right to aim the sensor. Adjust the sensor eye up • Objects that change temperature rapidly, such as heat- and down to obtain desired ing vents or air conditioners. These heat sources coverage range.
  • Page 4 TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light will not come 1. Light switch is turned off. Light comes on 1. Entryway Light may be sensing small 2. Light bulb is loose or burned for no apparent animals or automobile traffic (re-aim out.
  • Page 5 Ponga el interruptor de tiempo (ON- TIME), al fondo del detector, en la posición de prueba (TEST). 10 5 1 TEST Modelos SL-5610/15 Para AUTOMÁTICO: La luz del pasillo de entrada detectora de movimiento ON-TIME Ponga el interruptor de tiempo...
  • Page 6 INSTALACION ❒ Calafatee la placa trasera y la superficie de montaje con un sellador de silicón contra la intem- Para un mejor funcionamiento, instale el aparato a casi perie. 2,1 m del suelo. ❒ Coloque una bombilla de 60 Vatios de luz, máximo, en el portalámparas.
  • Page 7 ❒ Gire la base del detector Evite dirigir el control hacia: hacia la izqueirda y derecha para apuntario. Ajuste el ojo • Pozos de agua u objetos que cambien de temperatura del detector hacia ariba y rápidamente, como respiraderos de calefacción hacia abajo para obtener la o de aire acondicionado.
  • Page 8 GUIA DE INvESTIGACION DE AvERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se en- 1. El interruptor de luz está apaga- La luz se pren- 1. El control de luz puede estar detectan- ciende. de sin ninguna do animales pequeños o el trásito de 2.
  • Page 9 * Revient au mode automatique au lever du soleil. Note: Après mise en circuit, attendre enfiron minute pour que l’étalonnage du circuit soit complété. ESSAI Modèles SL-5610/15 ON-TIME Amener en position d’essai (TEST) l’interrupteur de temps en circuit (ON- Le luminaire d’entrée à détecteur de mouvement Heath ®...
  • Page 10 INSTALLATION ❒ Calfeutrer le rebord arrière du luminaire et la surface de montage avec un scellant silicone Pour un rendement optimal, montez le luminaire à résistant aux intempéries. environ 2,1 m au-dessus du sol. ❒ Installer une ampoule d’au plus 60 W dans la douille du luminaire.
  • Page 11 ❒ Faire tourner la base du Éviter de pointer l’appareil: capteur de droite à gauche pour orienter. Ajuster l’oeil • en direction d'objets dont la température change ra- du capteur de bas en haut pidement, tels que des bouches d'air chaud et des pour assurer la couverture climatiseurs.
  • Page 12 GUIDE DE DÉPANNAGE SYMPTÔME CAUSE POSSIBLE SYMPTÔME CAUSE POSSIBLE L’éclairage ne s’al- 1. L’interrupteur d’éclairage est en L’éclairage s’al- 1. Le luminaire d’entrée pourrait lume pas. position hors circuit. lume sans rai- détecter de petits animaux ou des 2. L’ampoule est desserrée ou brû- son apparente.

Ce manuel est également adapté pour:

Sl-5615