Télécharger Imprimer la page
Heath Zenith SL-5412 Installation
Heath Zenith SL-5412 Installation

Heath Zenith SL-5412 Installation

Masquer les pouces Voir aussi pour SL-5412:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Motion Sensor Light
Control for Canadian
Tire
Model SL-5412
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Plastic Hanger
Lamp Holders
Cover
Plate
Sensor
Light Control
Mounting Strap
Mounting Bolt
Rubber Plug
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
© 2003 DESA Specialty Products™
2 Shells
Gasket
6 Screws
(3 sizes included)
2 Wire
Connectors
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5
or 10 minute position.
MANUAL MODE
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Works:
Day
x
1
/
minutes for
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5 or 10 minutes
Flip light switch off
for one second then
back on*
595-5767-02
Night
x
x
x

Publicité

loading

Sommaire des Matières pour Heath Zenith SL-5412

  • Page 1 * resets to Auto Mode at dawn. Tire Note: When first turned on wait about 1 minutes for the circuitry to calibrate. Model SL-5412 TEST ON-TIME Put the ON-TIME switch on the bottom Features of the sensor in the TEST position.
  • Page 2 INSTALLATION Black to Black Mounting White to White Strap For easy installation, select an existing light with a wall switch for replacement. Rubber 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 Plug 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9...
  • Page 3 ❒ Loosen the clamp screw in TEST AND ADJUSTMENT Clamp the sensor ball joint and gen- Screw ❒ Turn on the circuit breaker and light switch. tly rotate the sensor. ❒ Walk through the coverage Ball NOTE: Sensor has about 1 minutes warm up area noting where you are Joint...
  • Page 4 TROUBLESHOOTING GUIDE If you experience a problem, follow this guide. SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not 1. Light switch is turned off. Lights stay on 1. A flood lamp is positioned too close to come on. 2. Flood light is loose or burned out. continuously.
  • Page 5 Manuel au choix, amanecer* pour Canadian Tire * Revient au mode automatique au lever du soleil. ESSAI Modèle SL-5412 ON-TIME Amener en position d’essai (TEST) l’interrupteur de temps en circuit (ON- Caractéristiques TIME) du bas du détecteur. 10 5 1 TEST •...
  • Page 6 Garniture de joint INSTALLATION noir / noir blanc /blanc Pour faciliter l’installation, choisir un appareil d’éclairage Bouchon de devant être remplacé et qui est déjà commandé par un Caoutchouc interrupteur. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 Vis de...
  • Page 7 ❒ Desserrer la vis de blocage ESSAIS ET RÉGLAGES Vis de de la rotule et faire pivoter le blocage ❒ Mettre en circuit le disjoncteur et l’interrupteur détecteur pour pointer. d’éclairage. ❒ Marcher dans la zone de Rotule couverture et noter à quel NOTE: Le capteur doit se réchauffer 1 minute avant endroit...
  • Page 8 GUIDE DE DÉPANNAGE Si vous éprouvez des difficultés, suivre ce guide. SYMPTÔME CAUSE POSSIBLE SYMPTÔME CAUSE POSSIBLE Les lampes 1. L’interrupteur d’éclairage est en posi- Les lampes 1. Un projecteur se trouve trop près du ne s’allument tion hors circuit. restent détecteur de la commande d’éclairage pas.