Télécharger Imprimer la page

Magmaweld ID 300E Mode D'emploi page 20

Publicité

Les langues disponibles

Les langues disponibles

20
Maintenance and Service
4.2 Error Codes
EN
Error Code
ERR-T1
E02
E08
E16
E32
USER MANUAL
Error
• Machine is overheated because of
Thermal
high ambient temperature of
Error
exceeding duty cycle
Power Module
• Error/Errors may exist in any
Error
electronic card
Control Supply
• Control supply voltage may have
Voltage Low
decreased
Mains Voltage
• Mains voltage may have decreased
Low
Mains Voltage
• Mains voltage may have increased
High
• Let the machine on for a while in
Cause
• Switch off and switch on. If the
• Contact the authorized service
• Check the mains connection cables
• Check the mains connection cables
Solution
order to cool down itself with the
cooling fan. After is cools enough,
you can go on welding
error still exists, check the mains
voltage whether it is within the
range of 340V-420V or not. If the
error still exists, contact the
authorized service
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
www.magmaweld.com
ID 300E

Publicité

loading