Intended Use
The product serves exclusively to raise the toilet seat and is therefo-
re only intended for installation on toilets. The purpose of the arm-
rests is to support the natural movement of the user when standing
up and sitting
down. Any other use is prohibited.
WARNING Risk of falling!
▸ Do not stand on this product.
▸ Do not use as a climbing aid.
WARNING Risk of falling!
The armrests are intended to be used on both sides evenly.
If pressure is applied on one side only, use only half of the
body weight.
At overload, there is a risk that the armrest will break.
Temperature for use: 10 - 40 °C
Max. user weight: 150 kg
Service Life
The expected service life of this product is three years when used in
accordance with safety instructions and intended use, stated in this
manual. The effective service life can vary according to frequency and
intensity of use.
Safety
WARNING Risk of injury!
▸ Do not use if defective.
Scope of delivery
Height
without armrests
▸ Fig. 1.1
2 cm
▸ Fig. 2.1
6 cm
▸ Fig. 3.1
10 cm
Assembly
CAUTION Risk of trapping!
▸ Be careful during assembly.
▸ Fig. 4.1
Height 2 cm
▸ Fig. 4.2
Height 6 cm
▸ Fig. 4.3
Height 10 cm
▸ Fig. 5 and 6.
▸ Fig. 7.1a
with armrests
▸ Fig. 7.1b
▸ Ensure that the red clips A engage at two points: first the pin B
and then the upper end of the clip C.
▸ To disassemble the armrest, first release the upper end of the
clip C and then the pin B.
▸ Fig. 7.2
without armrests
▸ Fig. 8.
2
Fig. 7.1b
EN
with armrests
▸ Fig. 1.2
▸ Fig. 2.2
▸ Fig. 3.2
Fig. 7.2
Cleaning and disinfection
The product can be cleaned and disinfected using commercially
available agents.
▸ Disinfect the product by wiping down all generally accessible sur-
faces with disinfectant (after disassembling the product, if possible).
!
All cleaning agents and disinfectants used must be effec-
tive, compatible with one another and must protect the
materials they are used to clean. For further information
on decontamination in Healthcare Environments, please
refer to 'The National Institute for Clinical Excellence'
guidelines on Infection Control www.nice.org.uk/CG002
and your local infection control policy.
▸ Clean by hand.
▸ Clean without scouring agent.
▸ Max. cleaning temperature 85 °C for three minutes.
Maintenance
and periodic inspection
The product is maintenance-free, provided the cleaning and safety
instructions outlined above are adhered to.
▸ Check product regularly for damage and to ensure that it is secu-
rely assembled.
Re-Use
The product is suitable for repeated use. The number of times it can
be used depends on how often and in which way the product is used.
Before reuse, clean and disinfect the product thoroughly and check
the safety functions, and reset if necessary.
Disposal
The disposal and recycling of used devices and packaging must comply
with the applicable legal regulations.
Warranty
We provide a manufacturer's warranty for the product in accordance
with our General Terms and Conditions of Business. Guarantee claims
can only be made through the relevant specialist dealer.