Air Conditioner Operating Instructions
(cont'd)
4) Press the FAN key Fig F (1) to select the desired
fan speed setting (Auto-Low-Med-High). Your
selection will appear in the display window
(each depression of the fan key will advance
to a different setting).
5) Press the SWING key Fig F (2) to activate the
automatic air swing (oscillating) feature and the
swing symbol will appear in the display window.
Fig G. To deactivate the air swing feature, press
the SWING key again.
6) The horizontal louvers open and close
automatically when the unit is switched on
and off. To adjust "air flow" direction, (up / down
only) adjust the center louver only up or down.
The blue indicator light will come on indicating the
air-conditioning mode is operational (there may be a
slight delay of 10-30 seconds before the cycle
begins, this is normal).
Cooling stops automatically when the set
temperature is achieved. Cooling resumes when the
room temperature rises above the set temperature
level. The temperature has no effect on the fan
operation. Therefore, the fan will operate
continuously (after the compressor has cycled off) to
maintain optimal temperature control.
C A U T I O N
During air
During air conditioning and dehumidifying
modes, if the compressor cycle is interupted
(unplugged, power failure,etc.) and reinstated
immediately thereafter, (within 3-5 minutes) a
"compressor protection circuit" is automatically
self-activated. The compressor cannot operate
during a "compressor protecton" condition. (this
is normal) It may take 3-5 minutes before the
"protection circuit" self-deactivates.
DO NOT ATTEMPT TO START THE UNIT
(COMPRESSOR) DURING THIS PERIOD.
Upon reinstating power to the unit all previous
settings (i.e. time, mode, fan speed, auto
timed programs) are lost and will have to be
re-entered.
1
2
Fig. 16
ATTENTION
Removal and/or displacement of the internal water
tank will cause the compressor to stop operating
(this is a safety feature). This condition will cause
the unit to beep (20 seconds) and the "water full"
(red) light will illuminate continuously until
corrected. The compressor cannot operate
during a "red" light condition.
Check the following;
1. Is the internal water tank full?
Empty and re-install water tank.
2. Has the water tank been accidently displaced?
Re-position water tank.
The "red" light will turn off automatically when the
water tank has been emptied and/or re-positioned.
10
Fig F
Fig G
Support pour
accrocher le
réservoir d'eau
externe
Drain inférieur
MISE EN GARDE
En modes de climatisation et de déshumidification, si le
cycle du compresseur est interrompu (par le
débranchement de l'unité ou par une panne de courant,
etc.) et immédiatement rétabli par la suite, (en dedans de
3 à 5 minutes) un circuit de protection du compresseur est
automatiquement activé. Le compresseur ne fonctionnera
pas en mode de protection. Ceci est normal et un délai
de 3 à 5 minutes pourrait se produire avant que le circuit
de protection du compresseur ne soit automatiquement
désactivé.
NE PAS TENTER DE FAIRE DÉMARRER LE
COMPRESSEUR DURANT CETTE PÉRIODE.
Avec la remise en service de l'unité (en tournant le
commutateur I/O), toutes les informations de programme
(c. à-d., heure, mode, vitesse du ventilateur, programmes
Vidage Directe
temporisés) devront être programmées de nouveau.
Sortie
D'eau
IMPORT ANT
( réservoir
externe)
Si l'indicateur de plein d'eau sur le panneau de
commande s'allume (pas clignote), installer le
résevoir d'eau externe ou placez un plateau
d'égouttement sous le drain inférieur et enlevez
les bouchons (pas en même temps) pour libérer
manuellement l'eau dans le sector de la puisard.
33F