WIRE THE SYSTEM
Wire the system as shown.
MAKE-UP AIR DAMPER
24V
24V
TRANSFORMER
BLACK (LINE)
WHITE (COMMON)
GREEN (GROUND)
WIRING DIAGRAM
ONE DAMPER
TEST THE SYSTEM
Once the damper, pressure switch, and probe is installed. Turn on the range hood to high speed and confirm that the damper opens.
Turn off the hood and check to see if the damper closes.
A qualified HVAC contractor should also ensure the proper operation and venting of all combustion equipment in the home.
FALSE TRIPPING
Under certain extreme conditions there could be false tripping of the damper (opening when the range hood blower is off). If false tripping
is encountered, place an in-line backdraft damper (6" model no. AK00029, 7" model no. AK00049, 8" model no. AK00069 between the
probe and the roof or wall cap.
SERVICE PARTS
50500133
Pressure Switch Kit
12110018
24V Transformer
54060012
6" Motorized Damper
54060013
8" Motorized Damper
MAKE-UP AIR DAMPER
PRESSURE
SWITCH
TRANSFORMER WIRING
24V
24V
WIRING DIAGRAM
MULTIPLE DAMPERS
24V CONTACTS
9
9
MODELS MUA006A • MUA008A
MAKE-UP AIR DAMPER
24V
24V
TRANSFORMER
BLACK (LINE)
WHITE (COMMON)
GREEN (GROUND)