MAXIMUM
USABLE
COOKING ZONES
The right and left cooking zones are controlled by two
separate power boards and the maximum total power
per each power board is 3700 W.
Should the cooking zones of one power board require
more than 3700 W, the last selected power level has
priority and the power of the other cooking zone is
automatically reduced to the remaining power available.
If this occurs, the cooking zone will display a flashing
figure for about 3 seconds before automatically
displaying the new power level.
This means for example that:
•
When setting a "Booster" programme for the second zone, the setting for the other
zone could be reduced to the remaining power available.
•
When setting a "Booster" programme for a zone and then another setting on the
second zone, if the total power exceed 3700 W the "Booster" programme is deleted
and the power reduced to the maximum power available.
THERMAL PROTECTIONS
The induction hob is fitted with safety devices to protect the electronic system and to protect
each cooking zone from overheating.
In case of overheating, one of the following automatic functions could be started by the
electronic system:
•
"Booster" program deleted and power reduced;
•
one or more cooking zone switched Off;
•
cooling fan motor of the induction unit switched on.
CHILDLOCK SAFETY
When not using the induction hob, set the childlock safety to prevent children from
accidentally switching on the cooking zones.
Ensure all cooking zones are switched Off, then turn the control knobs of the left cooking
zones simultaneously to the left (
up on the cooking zones display; then release the knobs.
To deactivate the childlock repeat the same procedure until
zones display; then release the knobs.
POWER
FOR
setting) and hold the knobs in this position until
THE
Controlled by
1st power board
lights up on the cooking
Controlled by
2nd power board
lights
171