8. The flame is smaller.
Pellets are not burning
enough. Dust has
accumulated on the
glass.
9. The flame goes out
and the message on the
display about the lack of
pellets (error code: E3).
10. Heating too weak.
11. Faulty ambient
temperature sensor
(error code: E1).
12. Smoke sensor
defective (error code:
E2).
13. When you turn on
the power, you may
notice that the fuse in
the switch is defective.
Not enough air in the
combustion chamber
No charge (pellets)
Too little pellet results in
too low a smoke
temperature.
The heat exchange pipes
are dusty.
The room temperature
sensor is damaged or
incorrectly attached.
The smoke detector is
defective or not attached
properly.
A short circuit in the
device.
1. Check, the sealing
properties of the sealing
strip on the door.
2. Check that the inlet
pipe or exhaust pipe is
not clogged
3. Increase the exhaust
fan speed to -5 or +5
(default 0)
4. If necessary, contact
the manufacturer's
service.
See problem (5)
Adjust the batch feeding
time.
Clean the heat exchange
tube.
Repair the sensor, correct
the installation method,
or contact the
manufacturer's service
department.
Repair the sensor, correct
the installation method,
or contact the
manufacturer's service
department.
Contact the
manufacturer's service
department.

Publicité