IMPORTANT: if the temperature inside the stove reaches 700
the pellet feeder will stop until the temperature drops to 650
g) Clock setting
Pressing the button 5 times allows you to go to the clock setting.
When the controls:
are blinking, set the current day and time with the
function/switching buttons (h).
3.3.4
Error lights
Disturbances in the proper operation of the stove may result in
displaying one of the error codes on the screen:
Error code
"E1"
"E2"
"E3"
Meaning
Room temperature
sensor error.
Thermoelectric
sensor
(thermocouple)
error.
Smoke temperature
sensor error, i.e. the
sensor sees the
°
Possible cause
• Damaged
temperature
sensor circuit
on the
motherboard.
• The
temperature
sensor itself is
defective.
• Cold solder.
• Deposition of
soot on the
sensor
affecting its
operation.
• Thermocouple
defective.
• No pellets in
the feeder.
°