6. Incorrect load
amount.
7. 15 minutes after
ignition, the oven shuts
down automatically and
displays an ignition error
(error code: E3)
There is a problem with
the connection between
the feeding engine and
the auger shaft.
No fuel in the tank.
The auger shaft channel is
blocked.
The auger shaft engine is
defective.
Too much pellet to burn in
the required time.
Not enough pellets for
proper combustion.
Lack of pellets or feeding
of pellets is not effective
enough, which causes
ignition failure.
The smoke detector
cannot correctly detect
the temperature of the
smoke.
A. Check that the screws
between the auger shaft
and the engine are not
loose or do not fit.
B. Check that the auger
shaft engine is not
damaged or that the
cable is properly
connected.
Pour fuel into the tank.
Check that the auger
shaft pipe is not blocked.
Contact the
manufacturer's service
department.
Adjust the batch feed
setting to -2 or -1
depending on actual
conditions (the factory
default setting is 3).
Adjust the batch feed
setting to +2 or +1 (the
factory default setting is
3).
Check the auger shaft
system and that the tank
is empty.
The smoke detector is
damaged or improperly
attached, contact the
manufacturer for smoke
detector replacement or
repair.