Télécharger Imprimer la page

Xpelair GX9 Instructions D'installation Et D'utilisation page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
GB
Xpelair GX9 and GXC9
Installation and Operating
Instructions
LEAVE THIS INSTRUCTION LEAFLET WITH THE
FAN, FOR THE BENEFIT OF THE USER.
6
All manuals and user guides at all-guides.com
These appliances are intended for connection to fixed wiring. Check
that the electrical rating shown on the fan matches the mains supply.
All installations must be supervised by a qualified electrician.
Installations and wiring must conform to current IEE Regulations (UK).
Local or appropriate regulations (other countries).
WARNING: THESE APPLIANCES MUST BE EARTHED.
It is the installer's responsibility to ensure that the appropriate Building
codes of Practice are adhered to. This appliance is not intended for
use by persons (including children and the infirm) with reduced
physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not play with the
appliance.
If you have any queries before installing these products or after they
have been installed, call the Xpelair Technical Hotline +44 (0)844
372 7760. Our Engineers are there to help you during Normal office
hours (UK only) and may be faxed at all other times +44 (0)844 372 7767.
Customers outside the UK may contact your local Xpelair Distributor.
1
GXC9 (cord operated) and GX9 fans have the following features:
Window, wall, panel or roof mounted.
Are fitted with silent operation back draft shutters. (GX9).
The GX9 can be extract, intake or "open shutter only", using an integral Fan
Selector Switch.
Trickle Ventilation setting.
Can be installed with a controller. (GX9 only).
If used with a speed controller, the GX9 can intake or extract at
If used with a speed controller, the GX9 can intake or extract at
selected speeds or at variable speed depending on the type of
controller, if used with an on/off switch, the GX9 will intake or extract
selected speeds or at variable speed depending on the type of
controller, if used with an on/off switch, the GX9 will intake or extract
at high speed.
at high speed.
2
If installing the fan with an on/off switch.
If installing the fan with an on/off switch.
3 core cable
A means for disconnection in all poles must be incorporated in the fixed
wiring in accordance with the wiring regulations.
6mm Blade Large Screwdriver, 3mm Blade Electricians Screwdriver, No's 1
& 2 Pozidriv Screwdrivers.
If wall mounting the fan, you will also need:
If wall mounting the fan, you will also need:
Mortar (to make good the hole).
Wall Kit WK9/8 or WK9/11 (Available from Xpelair) or a tube 253mm
internal diameter.
If window mounting the fan, you will also need:
If window mounting the fan, you will also need:
A single glazed non-operating window with a minimum glass thickness of
4mm.
If roof mounting the fan, you will also need.
If roof mounting the fan, you will also need.
Roof cowl RC9
Roof mounting plate XRP9/12 for flat roof installation. (Both items available
from Xpelair).
If installing the fan with a controller (GX9 only).
If installing the fan with a controller (GX9 only).
5 core cable. Note. Please check the instructions fro the controller.
3
Locate it as high as possible.
At least 205mm from the edges of the wall or Window frame to the centre
of the hole.
As far away as possible from and opposite to the main source of air
replacement to ensure airflow across the room(e.g. opposite the internal
doorway).
Near the source of steam or odours.
Not where ambient temperatures are likely to exceed 50
When the fan is installed in a room containing a fuel burning
appliance, precautions must be taken to avoid the backflow of gases
into the room from the open flue of the fuel burning appliance.
If the fan is intended to intake air, the inlet grille should be
sited at a distance of at least 0.5metre from the discharge
outlet of a flued heating or cooking appliance.
When intended for use in possible chemical corrosive atmospheres,
you must consult our Technical Service Department.
This product must not be installed in zone 0.
4
1. Check there are no buried Pipes or Cables e.g. Electricity, Gas, Water
behind the Switch location (in the Wall or above the Ceiling).
2. Lay in the Cable from the Isolating Switch to the Fan location.
3. Lay in the Cable from the Isolating Switch to the point of connection to the
Mains Supply.
4. Install the Isolating Switch.
5. Make all connections within the Isolating Switch.
WARNING: Do not make any connections to the Electrical Supply
at this stage.
For Australia only: These models are permanently connected to the supply
and operation is controlled by a remote switch. They should be
Directly wired to the supply through an approved 10A wall mounted surface
with at least 3mm clearance between contracts.
INSTALLING THE FAN
Description
What the installer will need
Where to locate the Fan
Installing the isolating Switch and Cables
o
C.
Se
le
Se
1.
2.
es
3.
4.
pa
5.
(Il
int
ch
6.
so
7.
8.
de
1.
inf
gri
sg
NO
sg
2.
La
Se
de
Se
pe
pia
1.
es
2.
ch
3.
e g
de
4.
de
5.
Ev
6.
og
1.
2.
no
3.
1.
(fig
2.
3.
se
1.
2.
po
1.
2.
op
3.
de
ve
po
la
1.
Pe
Pe
co

Publicité

loading

Ce manuel est également adapté pour:

Gxc9