Install the wireless 5-IN-1 sensor in an
open location with no obstructions above
and around the sensor for accurate rain
and wind measurement. Install the sensor
with the smaller end facing the North
to properly orient the wind direction
vane.
Secure the mounting stand and bracket
(included) to a post or pole, and allow
minimum 1.5m off the ground
Mounting guidelines:
1. Install the wireless 5-in-1 sensor at least 1.5m off the ground for better and more accurate wind
measurements.
2. Choose an open area within 150 meters from the LCD display Main Unit.
3. Install the wireless 5-in-1 sensor as level as possible to achieve accurate rain and wind measurements.
A bubble level device is provided to ensure a level installation.
4. Mount the wireless 5-in-1 sensor with the wind meter end pointing to the North to correctly orient direction
of the wind vane.
A. Mounting on pole (Pole Diameter 1"~1.3" (25~33mm)
B. Mounting on the railing