TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless.
Ductless installations require charcoal filters, available from
your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES
FOR INSTALLATION, DETERMINE WHICH VENTING
METHOD WILL BE USED AND CAREFULLY CALCULATE
ALL MEASUREMENTS.
RANGEHOOD ASSEMBLY
C -
CANOPY
A
-
CHIMNEY
S
-
RANGEHOOD MOUNT BRACKET
F
-
DUCT ADAPTER
G -
DUCTLESS GRATE
B
-
SUPPORT ROD (TO AID IN INSTALLATION ONLY)
FIGURE 1
All manuals and user guides at all-guides.com
INSTALLATION DIMENSIONS
The Axia chimney is adjustable and designed to meet varying
ceiling heights. FIGURE 2 illustrates the standard installation
for the Axia which requires the canopy to be mounted 24"
above the countertop.
FIGURE 2
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 35 feet if ducted with 6" round
ductwork. Calculate the length of the ductwork by adding
the equivalent feet in FIGURE 3 for each piece of duct in the
system. An example is given in FIGURE 4. For best results,
use no more than three 90° elbows. Make sure that there
is a minimum of 24" of straight duct between elbows if more
than one is used. Do not install two elbows together.
45˚ Elbow
7.0 feet
90˚ Elbow
5.0 feet
90˚ Flat Elbow
12.0 feet
Wall Cap
0.0 feet
FIGURE 3
WARNING
!
PERSONAL INJURY HAZARD
Because of the weight and size of the rangehood
canopy, two or more people are needed to move
and safely install the rangehood canopy.
Failure to properly lift rangehood could result in
damage to the product or personal injury.
9 Feet Straight Duct
9.0 feet
2 - 90˚ Elbows
10.0 feet
Wall Cap
0.0 feet
Total System
19.0 feet
FIGURE 4
Version02/02 - Page 4