User Guide 368 / 604-606
3.3.
Description and components location
Drain
Outlet
Meter cable
AC adapter connection
3.4.
Bypassing
The system must be equipped with a bypass. If a problem occurs, turn the valves to bypass the system as shown in the picture
below.
In
Normal
operation
4 .
Programming
A
Note:
After 5 seconds without keypad input, the unit returns to normal operation mode and display the time of day.
4.1.
Basic programming
A
Note:
has two different functions according to the controller used :
For 604 controllers : the function is the day interval setting.
For 606 controllers : the function is the volumetric capacity setting.
Time of day
A
Press
until desired hour appears then release.
Range from 0 through 23 hours.
The elapsed minutes will reset to zero when the hours are changed.
Brine dosage
A
Press
until desired brine dosage appears then release.
Range from 0.2 kg to 6.0 kg;
from 0.2 kg to 1.0 kg by increments of 0.05 kg;
from 1.0 kg to 3.0 kg by increments of 0.1 kg;
from 3.0 kg to 6.0 kg by increments of 0.5 kg.
Time clock regeneration (604 only)
A
Press
until desired interval appears then release.
Range from 0 through 30;
0 = Disabled;
0.3 = Regeneration every 8 hours : at 2, 10 and 18 hours;
0.5 = Regeneration every 12 hours : at 2 and 14 hours;
1 - 30 = Regeneration every X days (every 3 days in this example).
6 / 28
All manuals and user guides at all-guides.com
Inlet
Brine
Out
Regen button
Camshaft indicator
Injector screen
Refill flow controller
Delayed regen indicator
In
In Bypass
Regen setting button
Display
Salt button
Time button
Flow indicator (606 only)
Out
Ref. MKT-UG-007 / A - 14.10.2016