Battery Replacement
Under normal conditions, the original batteries in your UPS will last many years. See
"Important Safety Instructions" before replacing batteries. The batteries are designed for hot-
swap replacement (i.e. leaving the UPS in ON mode), but some qualified service personnel may
wish to put the UPS in the OFF mode and disconnect equipment before proceeding.
Procedure
Remove Front
1
Panel
Disconnect
2
Batteries
3
Remove/Dispose of
Batteries
4
Add Batteries
Connect Batteries
5
Attach connectors: black-
to-black and red-to-red.
6
Replace Front
Panel