Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems.
Failure to heed these warnings may affect your warranty.
UPS Location Warnings
• The UPS is designed for indoor use only in a controlled environment, away from excess moisture, heat/cold, conductive contaminants, dust or
direct sunlight.
• Leave adequate space around all sides of the UPS for proper ventilation.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit's internal
cooling, eventually causing product damage not covered under warranty.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.
• Do not modify the UPS's plug, and do not use an adapter that would eliminate the UPS's ground connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.
• The UPS contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support
equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors or extension cords to the output of your UPS. This might damage the UPS and may affect the surge suppressor and
UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason. There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries
in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing
battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery replacement should be performed
only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local
codes for disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling information. Tripp Lite offers a complete line of UPS
System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific
replacement battery for your UPS.
• Do not attempt to add an external battery pack to the UPS.
Copyright © 2010 Tripp Lite. All rights reserved. All trademarks are the property of their respective owners.
All manuals and user guides at all-guides.com
Owner's Manual
OMNI1500LCD
Not suitable for mobile applications.
5
Español
1111 W. 35th Street • Chicago, IL 60609 USA
www.tripplite.com/support
1
9
Français

Publicité

loading

Sommaire des Matières pour Tripp-Lite SMART1200LCD

  • Page 1 All manuals and user guides at all-guides.com Owner’s Manual SMART1200LCD, SMART1500LCD & OMNI1500LCD Not suitable for mobile applications. English Español Français Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems.
  • Page 2 All manuals and user guides at all-guides.com Quick Installation STEP 1: To install the UPS in a 4-post rack, attach the included mounting hardware to the UPS as shown in diagram . To mount the UPS in a 2-post rack, attach the included hardware to the UPS as shown in diagram .
  • Page 3 All manuals and user guides at all-guides.com Basic Operation (Front Panel) continued LCD Display The LCD Display indicates a variety of UPS operational conditions. All descriptions apply when the UPS is plugged into an AC outlet and turned on. The LCD Display can be rotated for easy viewing, regardless of whether the UPS is in a horizontal or vertical (“tower”) position.
  • Page 4 All manuals and user guides at all-guides.com Basic Operation (Rear Panel) continued Power Sensitivity Dial: This dial is normally set fully counterclockwise, which enables the UPS to protect against waveform distortions in its AC input. When such distortion occurs, the UPS will normally switch to providing PWM sinewave power from its battery reserves for as long as the distortion is present.
  • Page 5 All manuals and user guides at all-guides.com Manual del propietario SMART1200LCD, SMART1500LCD & OMNI1500LCD No apropiado para aplicaciones móviles. English Español Français Instrucciones de seguridad importantes gUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones y advertencias que deben seguirse durante la instalación, operación y almacenamiento de todos los UPS de Tripp Lite. La falta de observar estas advertencias podría afectar su garantía.
  • Page 6 All manuals and user guides at all-guides.com Instalación rápida PASO 1 : Para montar el UPS en un bastidor de 4 postes, conecte los accesorios incluidos al UPS como se observa en el diagrama . Para . Luego, con un ayudante montar el UPS en un bastidor de 2 postes, conecte los acesorios incluidos al UPS como se observa en el diagrama si es necesario, levante el UPS y móntelo en un bastidor estándar o en una caja de bastidor con los materiales suministrados por el usuario.
  • Page 7 All manuals and user guides at all-guides.com Operación básica (Panel frontal) continued Pantalla LCD La pantalla LCD indica diferentes condiciones de operación del UPS. Todas las descripciones se aplican cuando el UPS está conectado a una salida de CA y encendido La pantalla LCD puede ser girada para mejor visualización, ya sea que el UPS esté...
  • Page 8 All manuals and user guides at all-guides.com Operación básica (Panel posterior) continued Dial sensibilidad de energía: Este dial normalmente está regulado totalmente en el sentido contrario al reloj, lo que permite al UPS proteger contra distorsiones de forma de onda en su entrada de corriente alterna. Cuando ocurren dichas distorsiones, normalmente el UPS conmutará para proporcionar una onda sinusoidal PWM de energía de sus baterías de reserva por tanto tiempo como la distorsión continúe.
  • Page 9 All manuals and user guides at all-guides.com Manuel du propriétaire SMART1200LCD, SMART1500LCD & OMNI1500LCD Non approprié aux applications mobiles. English Español Français Consignes de sécurité importantes CONSERVEZ CES INSTRUCTIONS Ce manuel contient des instructions et avertissements qui doivent être suivis pendant l'installation, l'opération et l'entreposage de tous les systèmes Tripp Lite UPS. Ne pas tenir compte de ces mises en garde pourrait affecter votre garantie.
  • Page 10 All manuals and user guides at all-guides.com Installation rapide ÉTAPE 1: Pour monter l'onduleur UPS sur bâti dans un bâti à 4 montants, fixer la quincaillerie incluse avec l'onduleur comme le montre le schema . Pour monter l'onduleur UPS sur bâti dans un bâti à 2 montants, fixer la quincaillerie incluse avec l'onduleur comme le montre le schema .
  • Page 11 All manuals and user guides at all-guides.com Fonctionnement de base (panneau avant) suite Afficheur à cristaux liquides L'afficheur à cristaux liquides indique toute une gamme de conditions opérationnelles du UPS. Toutes les descriptions des témoins lumineux s'appliquent lorsque le UPS est branché dans une prise c.a. et en marche. L'afficheur à cristaux liquides peut être pivoté...
  • Page 12 All manuals and user guides at all-guides.com Fonctionnement de base (panneau arrière) suite Rotateur réglage de sensibilité d'alimentation : Ce rotateur est normalement réglé à fond dans le sens anti-horaire; cela permet à l'onduleur UPS d'assurer une protection contre les distorsions de forme d'onde à son entrée de secteur. Quand une telle distorsion se produit, l'onduleur passera normalement sur l'alimentation d'onde sinusoïdale MID à...

Ce manuel est également adapté pour:

Smart1500lcdOmni1500lcd