A - CONNEXIONS
J12
LINE EARTH
J1
10
VR1
VR2
VR3
J13
J10
J7
J5
J6
TF
MOTOR EARTH
J2
9
8
7 6
5
4
3
2
1
J3
14
13
12
11
15
J4
16
S1
JP1
JP2
J8
J11
J9
J1
L-N
230Vac 50/60Hz power supply
1
Single pulse contact (NA) K
2
Common to contacts
3
Contact for photocells (NC)
4
Common to contacts
5
Safety strip contact during opening and closing (NC)
J2
6
Common to contacts
7
Positive flash light indicator (max 20 W)
8
24Vdc positive voltage for safety strip self test power supply
9
24Vdc positive voltage for auxiliary unit power supply
10
24Vdc negative voltage for auxiliary unit power supply
11
Beacon power supply (24 Vdc)
12
Red LED connection to signal run down battery in flashing lamp
J3
13
K Cover single pulse contact (NA) on flashing lamp
14
Common to contacts
15
Antenna earthing
J4
16
Antenna plant
MOTOR +
Faston connector for motor wiring - red wire
J5
MOTOR –
Faston connector for motor wiring - black wire
ENCODER S
Faston connector for encoder wiring - white wire
J6
ENCODER -
Faston connector for encoder wiring - black wire
J7
Battery Charger
Connector for battery charger board
DO NOT TOUCH THE JUMPER! THE OPERATOR IS DISABLED IF THE
J8
JUMPER IS REMOVED!
LSC
Contact for closing stop limit switch
J9
LSO
Contact for opening stop limit switch
COM
Common to contacts
J10
Connector for no. 2 motor clutch SLAVE board
Connector for external 24Vdc radio receiver (not CRX models)
J11
RADIO
Built-in radio module (CRX models)
J12
PRI TRANSF
Faston connector for primary transformer connection
J13
SEC TRANSF
Faston connector per secondary transformer connection
VR1
TRIMMER RUN
Trimmer for high speed adjustment operations
TRIMMER
VR2
Trimmer for low speed adjustment operations
LOW SPEED
Trimmer for automatic closing time adjustment. DISABLED
VR3
TRIMMER TCA
DEFAULT AND DL9 LED OFF
JP1
Activation of radio code clearing
JP2
Available area for future applications and installations
P1
S1-PROG.
Programming control lever
F1
T3,5A
Mains supply input protection fuse
F2
T8A
Motor protection fuse
TF
130 VA transformer
53
G
B