Installation
- Finish plaster wall and tile up to the fitting template. When
doing so, seal wall openings against water splashes.
• In the case of tiles laid in mortar, pointing must be bevelled
outwards.
• In the case of prefabricated walls, seal with elastic sealing
compounds.
- Remove fitting template (A), see fold-out page I, fig. [1].
- Unscrew adjusting nut (B) and detach stop ring (C), discard
both parts.
- Install stop ring (D), see fig. [2].
- Fit clamp (E).
Mounting escutcheon, see figs. [3] and [4].
1. Install if necessary the compensation ring (G), see fig. [3].
2. Push sleeve (F) with the mark (F1) upward onto the mixer
shank, make sure that the marking point (F2) snaps into the
sleeve (F).
3. Grease seal (H) with the grease provided, see fig. [4].
4. Slide the escutcheon (J) over the sleeve (F).
5. Slide snap inserts (K) over screws (L) and secure
escutcheon (J) to the valve.
Do not use excessive force to tighten the screws.
6. Cover the screws with cover caps (M).
7. For assembly of the thermostat handle, see chapter
"Adjustment".
If thermostat is installed too deep, the fitting depth can
be increased by 1 1/8" (27.5mm) with extension set
Part No. 47 358, see fold-out page II and III.
Adjustment
Temperature setting, see fold-out page IV, figs. [5] and [6].
• Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat handle.
• After each service on the thermostat mixer.
1. Open volume control (N) and measure the temperature of
the water emerging with a thermometer, see fig. [5].
2. Turn the green regulator nut (O) clockwise - counter-
clockwise with a screwdriver until the water emerging has
reached a temperature of 100 °F (38 °C).
3. Fit the thermostat handle (P) so that the 100 °F mark on
the thermostat handle lines up with the mark (F1) on the
sleeve (F), see fig. [6].
4. Insert fixing ring (R).
5. Push on handle (S) or lever and screw on handle cap (T).
Reversed union (hot on right - cold on left).
Replace thermoelement (47 050) or (47 582), see replacement
parts fold-out page II and III, ref. No.: 47 282 (1/2")
and 47 379 (3/4").
Temperature limitation
When in proper calibration, the temperature range is limited
to 110 °F (42 °C). There is a safety check at 100 °F (38 °C).
If a higher temperature is desired, one can
exceed 100 °F (38 °C) by overriding the safety check.
1
English
Prevention of frost damage
When the domestic water system is drained, the thermostat
mixers must be drained separately, since check valves are
installed in the hot and cold water connections.
The complete thermostat assembly and check valves must be
unscrewed and removed.
Maintenance
For Maintenance, see figs. [4], [6], [7], [8] and fold-out page II
and III.
Inspect and clean all parts, replace if necessary and grease
with special valve grease.
I.Thermoelement
1. Turn thermostat handle (47 570) or lever thermostat
handle (47 495) to the 100 °F (38 °C) safety check, see
fold-out page II and III and fig. [6].
2. Remove handle cap (T) and handle (09 698) or
lever (47 490).
3. Take out fixing ring (R).
4. Pull off thermostat handle (P).
5. Remove escutcheon (J), see fig. [4] and installation,
points 4 - 6, in reverse order.
6. Close both isolation valves (I).
7. Pull sleeve (F) from the mixer shank by pressing
down the tongue (U), see fig. [7].
8. Extract clamp (E).
9. Pull stop ring (D) until resistance is encountered
(approximately 3/8" [10mm]), see fig. [8].
10. Unscrew stop ring (D) complete with regulator nut (O).
11. Unscrew thermoelement (47 050, 47 582) with 24mm
open-ended wrench, see fold-out page II and III.
Temperature adjustment is necessary after each service of the
thermostat cartridge (see Adjustment).
II. Non-return valve
1. Proceed as for maintenance of thermoelement, points 1 - 6.
2. Unscrew non-return valve (V) or (W) with 17mm socket
wrench or 10mm allen wrench.
3. Remove non-return valve (W1) and filter (W2).
Reassembly should be carried out in reverse order.
Replacement parts, see fold-out page II and III
(* = special accessories).
Care
Instructions for care of this fitting will be found in the Limited
Warranty supplement.