3.1.5
Safety cable
When hung or flown the
fixture must be secured by
an additional hanging
accessory (such as a
safety bond or cable) of
suitable length.
The combined weight of
both the fixture and the
accessories must be
considered when
choosing the load-bearing
capability of safety cable
or bond.
Safety cables or bonds
must be securely attached
to the back of the fixture
and be as short as
possible, or rolled up as
necessary, to minimise
travel distance should the
fixture be dislodged.
3.2
Electrical
3.2.1
LED source
Never touch or scratch LED surface.
Never use compressed air directly on LED chip.
3.2.2
Power
Voltage
Frequency
90
264 V
47-63 Hz
Class 1 product. This luminaire must be grounded.
Must be connected directly to AC power. Do not connect to dimmer power.
Automatic power detection.
4A breaker.
Daisy chain : maximum of 10 units (230V) / 5 units (120V)
Daisy chain (with delivered power cable) :
All manuals and user guides at all-guides.com
Power supply
Input power
1,5 A / 330 W @ 230V
2,8 A / 330 W @ 120V
3,3 A / 330 W @ 100V
Max. 3.6A
Standby mode: 10 W
EN -5-
Connectors
Neutrik powerCON TRUE1
ref. NAC3PX (max. 20A)
Maximum:
10 units (230V)
5 units (120V)
EN

Publicité