HPL 9S-TU(R)W - HPL 18S-TU(R)W
for domestic hot water
for circulation pipe
for expansion vessel
6.12 Anode diameter
6.13 Anode length
6.14 Anode connection thread
6.15 Weight of the transport unit(s)
incl. packaging
7
Electrical connection
7.1
Supply voltage / fusing / RCD type
7.2
Control voltage / fusing by WPM
7.3
Degree of protection according to EN 60529
7.4
Starting current limiter
7.5
Rotary field monitoring
7.6
Starting current with soft starter
7.7
Nominal power consumption A2/W35/ max. power consumption
7.8
Nominal current A2 /W35 / cos
7.9
Power consumption of compressor protection
(per compressor)
7.10 Power consumption of fan
7.11 Control voltage, fusing
7.12 Supply voltage / fusing
(∑ P = 3.5 kW)
Supply voltage / fusing
(∑ P = 3.5 kW)
8
Complies with the European safety regulations
9
Additional model features
9.1
Type of defrosting
9.2
Frost protection, condensate tray /
Water in device protected against freezing
9.3
Maximum operating pressure (heat sink)
9.4
Energy efficiency class / energy efficiency (low temperature)
9.5
Energy efficiency class / energy efficiency (mean temperature)
4
10 Heat output COP
10.1 Heat output / COP
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? t
2. Operation with 2 compressors
3. Operation with 1 comressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in
particular the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care,
commissioning and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/
W35: outside air temperature 7 °C and heating water flow temperature 35 °C.
5. Standard nominal flow only possible with an electronically controlled circulating pump with actuation via heat pump manager.
6. The heat output and COP is reduced by approx. 5 % in lower operation
7. When the optional weather protection hood (accessory) is used. the sound pressure level in outlet direction is reduced by 3 dB(A).
8. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
9. condition as delivered 6 kw
10.Note that additional space is required for pipe connections, operation and maintenance.
11.See CE declaration of conformity
12.The heat circulating pump and the heat pump manager must always be ready for operation.
13.The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
www.glendimplex.de
inches
inches
inches
HWK
mm
HWK
mm
HWK
inches
HWK
kg
A
4
kW
A / ---
W / ---
W
HWK
HWK
HWK
HWK
12
bar
Performance level
at A-7 / W35
kW / ---
at A2 / W35
kW / ---
at A7 / W35
kW / ---
at A7 / W45
kW / ---
at A7 / W55
kW / ---
at A10 / W35
kW / ---
452168.66.05 · FD 0010
1" AG
3/4" IG
1" AG/FL
33
690
1 1/4" IG
210
3~/N/PE 400 V (50 Hz) /
3~/N/PE 400 V (50 Hz) /
C10 A / A
1~/N/PE 230 V (50 Hz) /
1~/N/PE 230 V (50 Hz) /
4 AT
IP 24
Soft starter
Yes
21
1.7 / 3.3
3.1 / 0.8
70 / thermostatically
70 / thermostatically
controlled
up to 100
1~ / N / PE 230V (50Hz) /
1~ / N / PE 230V (50Hz) /
B63A
3~ / N / PE 400V (50Hz) /
3~ / N / PE 400V (50Hz) /
B25A
1~ / N / PE 230V (50Hz) /
1~ / N / PE 230V (50Hz) /
B16A
3~ / N / PE 400V (50Hz) /
3~ / N / PE 400V (50Hz) /
B10A
11
Reverse circulation
Reverse circulation
Yes
3.0
A++ / 177 %
A++ / 173 %
A++ / 127 %
A++ / 128 %
EN 14511
1
2
1
5.5 / 3.3
---
7.2 / 3.2
9.5 /
7.2 / 4.3
---
4.1(4.3)
8.4 / 4.9
---
11.3 / 4.8
8.2 / 3.8
---
10.8 / 3.9
8.0 / 3.0
---
10.0 / 3.1
8.9 / 5.3
---
12.0 / 5.1
1" AG
1" AG
3/4" IG
3/4" IG
1" AG/FL
1" AG/FL
33
33
690
690
1 1/4" IG
1 1/4" IG
210
210
3~/N/PE 400 V (50 Hz) /
C10 A / A
C13 A / A
1~/N/PE 230 V (50 Hz) /
4 AT
4 AT
IP 24
IP 24
Soft starter
Soft starter
Yes
Yes
19
21
2.38 / 4.0
3.24 / 6.8
4.3 / 0.8
5.9 / 0.8
70 / thermostatically
controlled
controlled
up to 150
up to 200
1~ / N / PE 230V (50Hz) /
B63A
B63A
3~ / N / PE 400V (50Hz) /
B25A
B25A
1~ / N / PE 230V (50Hz) /
B16A
B16A
3~ / N / PE 400V (50Hz) /
B10A
B10A
11
11
Reverse circulation
Yes
Yes
3.0
3.0
A++ / 168 %
A++ / 133 %
EN 14511
EN 14511
2
1
---
5.6 / 3.3
---
7.3 / 4.3
13
---
8.4 / 5.0
---
8.1 / 3.9
---
7.7 / 3.2
---
8.8 / 5.4
English
2
10.5 / 3.2
12.3 / 3.9
13
(4.0)
EN-11