12 Device information
1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Installation location
2.4
Thermal energy metering
2.5
Performance levels
3
Operating limits
3.1
Heating water flow / return
1
3.2
Air (heating)
4
4
Flow
/ sound
4.1
Heating water flow heat pump circuit / free compression
Nominal flow in accordance with EN 14511
4.2
Minimum heating water flow rate
Heat pump circuit
4.3
Sound power level according to EN 12102
Normal operation / reduced operation
4.4
Sound pressure level at a distance of 10 m (air outlet side)
Normal operation / reduced operation
4.5
Air flow
Normal operation / reduced operation
4.6
Sound power level
4.7
Sound pressure level at a distance
of 1m
5
Technical data
5.1
Heat generation
5.2
Buffer tank
Nominal capacity
Permissible operating temperature
max. permissible operating pressure
Electrical pipe heater
Immersion heater
5.3
Domestic hot water cylinder
Usable capacity
Heat exchanger area
Permissible operating temperature
Permissible operating pressure
Immersion heater
5.4
Start-to-leak pressure, safety valve
6
Dimensions, weight and filling quantities
6.1
Device dimensions without connections
6.2
Device connections for heating
6.3
Weight of the transportable unit(s) incl. packaging
6.4
Refrigerant / total filling weight
6.5
6.6
6.7
Lubricant / total filling quantity
6.8
Volume of heating water in device
10
6.9
Device dimensions
6.10 Tilted dimension
6.11 Device connections
for heat generator
unmixed heating circuit
EN-10
Heat Pump / Hydro tower
1
at A7 / W35...30
at A7 / W45...40
at A7 / W55...47
6 7
8
6 7
6
HWK
HWK
HWK
HWK
HWK
HWK
HWK
HWK
HWK
HWK
452168.66.05 · FD 0010
HPL 9S-TUW
Air
Universal with hydro
tower
Integrated (hydro tower) Integrated (hydro tower) Integrated (hydro tower)
Outdoors / Indoors
Integrated
1
up to 60 ± 2 / from 18
°C
-22 to +35
°C
1.5 / 41000
m³/h / Pa
m³/h / Pa
1.4 / 46000
5
m³/h / Pa
0.9
/ 67000
1.2
m³/h / Pa
53 / 53
dB(A)
25 / 25
dB(A)
2700 / 2100
m³/h
dB(A)
42
35
dB(A)
external
litres
100
°C
85
bar
2,0
kW
9
2, 4 or 6
kW
up to 6
litres
277
3,15
°C
95
bar
10,0
kW
1,5
bar
2,5
H x W x L mm
1650 x 910 x 750
inches
G 1 1/4" external thread G 1 1/4" external thread G 1 1/4" external thread
kg
225
type/kg
R410A / 3.9
2088 / 8
yes
type/litres
Polyolester (POE)/1.2
Litres
2.6
1920 x 740 x 950
H x W x L mm
mm
2000
inches
1" AG/FL
inches
1" AG/FL
HPL 9S-TU(R)W - HPL 18S-TU(R)W
HPL 12S-TUW
HPL 18S-TUW
Air
Universal with hydro
Universal with hydro
tower
Outdoors / Indoors
Outdoors / Indoors
Integrated
Integrated
1
up to 60 ± 2 / from 18
up to 60 ± 2 / from 18
-22 to +35
-22 to +5
1.9 / 18000
1.5 / 40900
1.8 / 24000
1.4 / 45900
5
1.2
/ 55000
1.4
1.4
54 / 53
26 / 25
4700 / 3600
5500 / 3200
42
35
external
100
85
2,0
9
2, 4 or 6
2, 4 or 6
up to 6
277
3,15
95
10,0
1,5
2,5
1650 x 910 x 750
1650 x 910 x 750
265
R410A / 4.78
R410A / 5.9
2088 / 9
2088 / 12
yes
Polyolester (POE)/1.2
Polyolester (POE)/1.2
3.8
1920 x 740 x 950
1920 x 740 x 950
2000
1" AG/FL
1" AG/FL
www.glendimplex.de
Air
tower
2
2
3
/ +35
5
/ 66900
1.4
54 / 53
26 / 25
42
35
external
100
85
2,0
9
up to 6
277
3,15
95
10,0
1,5
2,5
295
yes
3.8
2000
1" AG/FL
1" AG/FL

Publicité