REFRIGERATOR CABINETS
4 OPERATION
4.1 PRELIMINARY INSPECTION OPERATIONS
Wait the necessary time for the equipment to reach
the set temperature before storing food inside of it.
Do not put hot foods or beverages inside the refri-
gerator.
Store the products inside the perimeter defined by
the grills in order to prevent blocking the flow of air.
Do not obstruct the fan intake area.
Do not obstruct the upper part of the refrigerator or
the air intakes when the REFRIGERATOR CABINET is
in operation or under electrical power.
4.2 START-UP
At the first start-up, make sure the REFRIGERATOR CABINET was
transported only in a vertical position: otherwise wait 8 hours
from the time it was positioned before proceeding with start-up.
Turn on the equipment by pressing the general switch to "I" (FIG.
11, POS. 6).
4.3 TEMPERATURE ADJUSTMENT
Adjust the temperature using the electronic thermostat (FIG. 11, POS. 5) as indicated in the ATTACHED MANUAL (Digital electronic controller)
4.4 SHUT-DOWN
To shut down the REFRIGERATED CABINET, just press the main switch to the "0" position (FIG. 11, POS. 6); the light on the key will shut off.
To isolate the refrigerator from electrical power, remove the plug from the outlet.
4.5 DEFROSTING
Defrosting the REFRIGERATOR CABINET is completely automatic. Defrosting "NORMAL TEMPERATURE" (NT) systems occurs automatically
every 4 hours. Defrosting lasts 30 minutes.
Defrosting the REFRIGERATOR CABINET is completely automatic. Defrosting "LOW TEMPERATURE" (LT) systems occurs automatically every
4 hours. Defrosting lasts 40 minutes.
4.6 LED INDICATION FOR DEBATTER MODEL
There is a two colour LED indicator on the DEBATTER model (FIG. 1, POS. 5):
-
GREEN LED on: indicates the DEBATTER system is operating normally;
-
RED LED on: indicates the DEBATTER system is NOT operating normally; IN THIS CASE, CALL TECHNICAL ASSISTANCE.
Next to the LED there is a sticker (FIG: 12) that explains the meaning of the two colours
Do not in any way remove the CONVEYOR (FIG. 1,
POS. 6) from the REFRIGERATOR CABINETS with DE-
BATTER. Assembly and dis-assembly of the conveyor
must be performed by qualified and authorized
technicians.
After ONE YEAR of operation the UV LAMP in the
DEBATTER system must be replaced. IN THIS CASE,
CALL TECHNICAL ASSISTANCE
FIG. 11
6
5
FIG. 12
(GREEN LED
on)
(RED LED
on)
UK