Télécharger Imprimer la page

SEA 23024005 Mode D'emploi page 5

Publicité

Les langues disponibles

Les langues disponibles

Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
The correct operation of the Anemometer can be verified at
installation as follows: connect the anemometer to the terminal
board, manually turn the anemometer, and simultaneously the
control board will send the command for the mechanism to
raise for a period of 5 seconds.
P
ROGRAMMING BUTTONS AND
SEL button: selects the type of function to be memorised,
The selection is indicated by a flashing Led. By repeatedly
pressing the button it is possible to choose the desired func-
tion. The selection will remain active for 15 seconds indicated
by a flashing Led; if no other operations are executed during
this period the control board will return to its previous state.
SET button: programs the information relative to the type of
function previously selected by the SEL button.
Led signals
Led on: memorised function.
Led off: non memorised function.
Led flashing: selected function.
Selectable functions
LED REF. LED OFF
1) LED 1
No code
2) LED 2
Motor speed at max (2 min.)
3) LED 3
Wind security for 25 Km/h
1)
LED 1
Functions with one or two remote control commands
It is possible to memorise one or two remote control com-
mands during the programming stage. One code can be used
for a cyclical function (raising/lowering), whilst two different
codes allows different commands, the first for raising and the
second for lowering.
Programming
The transmission code is programmed in
the following manner: press the SEL button until the LED 1
flashes, immediately transmit the pre-selected code with the
desired remote control, as soon as the LED 1 begins to flash
rapidly send the second code to be memorised, when the LED
1 remains lit, the programming is complete. If the second code
is not sent within 10 seconds the control unit will exit the pro-
gramming phase and select the function with only one code of
the remote control. When 31 codes have been stored all three
LEDs will flash, indicating that no other codes can be stored.
Programming through Radio command.
This procedure, consents to enable the programming, without
direct intervention of the SEL task on the panel, but executing
the operation at a distance, allows the programming of trans-
mission codes without the having to use the SEL button on
the central direct.
The ability of programming is executed in the following man-
ner: send in a continuous manner for max. 10 seconds the
codes of the radio command previously memorised, at the
same time the panel will enter into programming mode as ex-
plained above.
Ability of programming through Radio command.
The panel is furnished by the builder with the radio command
disabled, if you wish to enable the function, proceed in the fol-
lowing manner: the panel board is powered by an output of
230VAC, keeping the SELL task pressed, at the same time
you will obtain a brief flashing of all the Leeds and the pro-
gramming will be complete.
If you wish to disable the function previously enabled, repeat
the operation or follow the RESET procedure.
Cancellation
To cancel all stored codes press the SEL
button and LED1 will start to flash. Then press the SET but-
ton. The procedure is now complete and LED1 will stop flash-
ing.
®
SEA S.r.l.
DIREZIONE E STABILIMENTO:
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. 0861 588341 r.a. Fax 0861 588344
L
S
ED
IGNALS
LED ON
Tx code stored
Motor speed stored
Wind security stored
http://www.seateam.com
e-mail:seacom@seateam.com (Uff. Comm.le)
English
2)
LED 2
Programming the motor operating time
The control unit is factory supplied with a motor time of two
minutes (LED2 OFF).
To program the motor time, close the rolling gate and proceed
as follows: Set the SEL button on the flashing LED2, then
continuously press the SET button, the rolling shutter will start
the opening; when you have reached the required height, re-
lease the SET button key and at the same time the motor time
storage will be completed and the LED2 will remain lit and
fixed.
Using an automated device with an incorporated stroke end,
we advise you to set a motor time of a few seconds more
when the rolling shutter has reached its end of stroke.
If you want an infinite motor time, carry out the same storage
procedure, keeping the SET button continuously pressed, less
two seconds. After two seconds the LED2 will remain lit and
fixed, and the infinite motor time will be stored. Repeat the
whole operation in the case of error.
3)
LED 3
Displaying wind threshold programs
To display the wind threshold selections use the SEL button to
select LED3. The LED will flash twice to show the memorized
wind threshold. Every double flash indicates an increase of 5
km/h. For example, five flashes equals 25 km/h.
Wind security threshold from 5 to 40 km/h
The unit has an intervention threshold for wind security at 25
km/h (LED3 OFF).
To program the wind security threshold use the SEL button to
select LED3, then press SET to start the programming proc-
ess. LED3 with start to flash twice. Every double flash indi-
cates and increase of 5 km/h. Press SET when the desired
threshold has been reached. The selection will be stored and
LED3 will remain lit.
NOTE: five double flashes of LED3 equals 25 km/h.
If a mistake is made during the programming process the
above steps can be repeated.
R
ESET
To reset the unit to its factory settings, press SEL and SET at
the same time to light all the LEDs, which will then go out
when the reset is complete.
SEA s.r.l.
change
are conformant to all of the requirements laid out in the EC
directive number: 99/5 which are based on the following
standards:
- EN 301 489-1/3; - EN 300 220-1/3 ; - EN 60730-1.
The samples which have been tested meet essential re-
quirements which have been specified above, on the basis
of the results of the tests.
Rev.01 - 10/2008
seatec@seateam.com (Uff. Tecnico)
D
C
E C L AR AT I O N O F
O N F O R M I T Y
declares that the products: Electronic Ex-
cod. 23024005

Publicité

loading