Multi-function electronic programming unit for automated
blinds and sun-shades. The unit's dimensions have been re-
duced.
T
D
ECHNICAL
ATA
- Power supply:
- Motor output:
- Working temperature:
- Radio receiver:
- Op. transmitters:
- Memorizable TX codes:
- Unit dimensions:
- Container:
- Protection capability:
CN1 T
B
ERMINAL
OARD
1: 230V~ input (Phase).
2: 230V~ input (Neutral).
3: Opening motor output (Up).
4: Common motor output.
5: Closing motor output (Down).
CN2 T
B
ERMINAL
OARD
1: T1 push-button input (NA).
2: Common GND Signal input.
3: T2 push-button input, down (NA).
4: T3 push-button input, cyclical (NA).
5: Common GND Signal input.
6: T4 Anemometer input (NA).
7: Aerial earth input.
8: Aerial pole input.
®
SEA S.r.l.
DIREZIONE E STABILIMENTO:
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. 0861 588341 r.a. Fax 0861 588344
23024005
230V~ 50/60Hz 2,5W
230V~ 500W Max
-20?85°C
refer to type
12-18 Bit or Rolling Code
31 UP, 31 DOWN or 31 P/P
110x121x47mm
ABS V-0
C
ONNECTION
C
ONNECTION
English
I
MPORTANT NOTICE FOR THE INSTALLER
- In order for the receiving part of the radio to function
correctly, in cases where two or more centres are used, it
is advisable to install them at a distance of at least 3 me-
ters from each other.
- The centre does not have any type of sectioning
mechanism, it is therefore the responsibility of the installer
to see to the installation of a sectioning device within the
plant.
- The fixing of the electricity supply cables and their con-
nection, must be guaranteed by means of the assembly of
the cable presses which are provided in the packaging.
G
ENERAL OR GROUP CENTRALIZATION
Central control using cable control
The central control by cable of two or more units allows the
simultaneous raising or lowering of connected blinds. The link
is carried out through a bus of three parallel lines at inputs T1,
T2 and the common GND Signal.
Central control using remote control
IP 54
The central control by remote control of two or more units al-
lows the simultaneous raising or lowering of the blinds. The
central control follows two identical codes from the remote
control (the first to raise and the second to lower the blinds)
for all units or for a group within 20 metres of the command
point, allowing greater control. Therefore it is advisable to take
care when selecting the installation location. Performance is
not only related to the technical specifications of the device
but can also vary according to the radio-electrical conditions at
the chosen location.
S
ETTINGS
SW1
Step by step
1) Step by step (Dip 1 and 2 OFF)
Operation is cyclical when either the button strip or the radio
control is used (Start - Stop - Start), if no stop command is
give, the control board will stop the mechanism at the end of
the programmed motor time.
When the anemometer is connected, the control board sends
the command to raise the mechanism each time the wind ex-
ceeds the selected trigger threshold.
2) Step by step + Aut. closing (Dip 1 ON and Dip 2 OFF)
The device will follow the same step by step function de-
scribed in point 1, but with the difference that when the wind
velocity is greater than the set speed, the control board gives
only one command to raise the mechanism, once the atmos-
pheric disturbance has passed, after an interval of 5 minutes
in which the wind velocity is less than the set threshold, the
control unit will automatically lower the blind or shade. This
feature is excluded if the command to raise the mechanism is
given by both the button strip and the radio control.
3) Person present (Dip 1 OFF and Dip 2 ON)
In this mode the control needs to be kept active to keep the
blind motor running. Releasing the control will stop the motor.
4) Anemometer Test (Dip 1 and 2 ON)
Rev.01 - 10/2008
http://www.seateam.com
e-mail:seacom@seateam.com (Uff. Comm.le)
seatec@seateam.com (Uff. Tecnico)
SW1
S/S + Closing
Person present
SW1
SW1
Test