Télécharger Imprimer la page

Ancona AN-1282 Instructions D'utilisateur page 5

Sous l'armoire 30"

Publicité

Les langues disponibles

Les langues disponibles

VENTING REQUIREMENTS:
Vent system must terminate to the outside
(Roof or side wall).
DO NOT terminate the vent system in an attic
or other enclosed area.
DO NOT use 4" (10.2 cm) laundry-type wall
caps.
Use metal/aluminum vent only. Rigid metal/
aluminum vent is recommended.
DO NOT use plastic vent.
Always keep the duct clean to ensure proper
airflow.
Calculate
the
installation:
1. Distance from the floor to the ceiling
2. Distance between the floor to the
countertop/stove
3. Distance between the cooking surface to the
range hood (recommended minimum 24"
electric cooktop, 30" gas cooktop)
4. Height of hood and duct cover
For the most efficient & quiet operation:
A distance of 24" minimum is recommended
between electric stove top and the bottom of range
hood, and 30" between gas stove top and bottom of
range hood. Maximum 30".
It is recommended that the range hood be vented
vertically through the roof through 6" (15.3 cm) or
bigger round metal/aluminum vent work.
The size of the vent should be uniform.
Use
no
more
Make sure there is a minimum of 24" (61 cm) of
straight vent between the elbows if more than one
elbow is used.
DO NOT install two elbows together.
The length of vent system and number of elbows
should be kept to a minimum to provide efficient
performance.
The vent system must have a damper. If roof or
wall cap has a damper, DO NOT use damper (if
supplied) on top of the range hood.
Use silver tape or duct tape to seal all joints in the
vent system.
Use caulking to seal exterior wall or roof opening
around the cap.
following
figures
than
three
90°
elbows.
HEIGHT & CLEARANCE:
before
5

Publicité

loading