Télécharger Imprimer la page

Bosch VGD553FR0 Manuel D'utilisation Et Notice D'installation page 25

Masquer les pouces Voir aussi pour VGD553FR0:

Publicité

Les langues disponibles

Les langues disponibles

Undo the internal setting screw.
6.
Fit the control knob and heat up the oven for 15
7.
minutes.
General nozzle table
Gas type/burner
Natural gas G20/oven burner
Natural gas G20/grill burner
Liquid gas butane/propane G30/
G31/oven burner
Liquid gas butane/propane G30/
G31/grill burner
Nominal operating pressure
Your appliance's nominal operating pressure is:
¡ For natural gas – NG (G20) 20 mbar/2.0 kPa
¡ For liquid gas – LPG (G30) 30 mbar/3.0 kPa
¡ For liquid gas – LPG (G31) 37 mbar/3.7 kPa
You must operate your appliance with these pressure
values. All information on your appliance's rating plate
relates to these pressure values. The manufacturer
shall accept no liability for the functionality and power
of your appliance or for other risks id you operate your
appliance with pressure values that differ from those
specified for your appliance.
mbar
Nozzle
number
20
135 (H1)
20
130 (H3)
28 -
90 (H1)
30/37
28 -
83 (S)
30/37
Turn the controller to the minimum position.
8.
Remove the control knob.
9.
Adjust the internal adjustment screw until a stable
10.
flame is burning correctly.
If required, loosen the adjustment screw to increase
the gas flow. Tighten the adjustment screw to re-
duce the gas flow. The setting is correct when the
height of the small flame is approx. 3 to 4 mm.
Tighten the adjustment screw in the case of a liquid
connection.
Attach the control knob.
11.
Ensure that the flame does not go out if you quickly
12.
change the gas flow from maximum to minimum
and vice versa, and if you open and close the appli-
ance door.
Bypass
Power in
watts
Gap
3600
3000
58
3600
3000
Note: If you are operating your appliance with liquid
gas, use a gas pressure regulator. The pressure regu-
lator must be connected and maintained by a licensed
expert.
17.12 Removing the appliance
Disconnect the appliance from the power supply.
1.
Undo the fastening screws.
2.
Lift the appliance slightly and pull it out completely.
3.
Installation instructions en
Minimum
Maximum consump-
power in
tion
watts
1200
G20: 352 l/h
G20: 298 l/h
1200
G30: 269 g/h
G31: 264 g/h
G30: 218 g/h
G31: 214 g/h
25

Publicité

loading