G
IMPORTANT INSTRUCTIONS FOR THE SAFETY
B
ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE
INSTRUCTIONS
KEEP THESE INSTRUCTIONS WITH CARE
1° - If it is not forecast in the electric gearcase, install a switch of magnetothermic type
upstream, (omni polar with minimum port of the contacts of 3mm) with a check of
conformity to the international standards. Such devise must be protected against the
accidental lockup (for example by installing inside a locked board).
2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F type
with 1,5 sqmm minimum section and, however, to keep to the IEC 364 and installation
standards in force in your country.
3° - Positioning of a possible couple of photoelectric cells: the radius of the photoelectric
cells must be at a height of no more than 70 cm from the ground and at a distance not
superior to 20 cm from the motion plane of the door. Their correct working must be
verified at the end of the installation in accordance with point D.3.2 of the EN 12453.
4° - To fulfil the limits set by EN 12453, and in case the peak force exceeds the normative
limit of 400 N it is necessary to have recourse to the active presence survey on the
whole height of the door (up to max 2,5 m) - The photocells, in this case, must be
applied in accordance with the point D.4.1 of the EN 12453.
N.B.: The earthing of the system is obligatory.
The data described in this handbook are purely a guide.
RIB reserves the right to change them in any moment.
Carry out the system in the respect of the standards and laws in force.
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
ATTENTION - THE INCORRECT INSTALLATION CAN CAUSE SERIOUS DAMAGES
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° - This handbook is exclusively addressed to the specialized personnel who knows the
constructive criteria and the protection devices against the accidents for motorized
gates, doors and main doors (follow the standards and the laws in force).
2° - The installer will have to issue a handbook to the final user in accordance with the
12635.
3° - The installer will have to put the tags warning against the entrapping dangers near
the controls and the horizontally pivoted door.
4° - Check frequently the system, in particular cables, springs and supports to find
out possible unbalances, wear signs or damages. The final user must not operate
electrically the horizontally pivoted door if this needs maintenance or repair, since a
failure in the installation or a non correctly balanced barrier can provoke wounds.
5° - Before proceeding with the installation, the installer must forecast the risks analysis
of the final automatized closing and the and the safety of the identified dangerous
points (Following the standards EN 12453).
6° - Before installing the motion motor, the installer must verify that the door is in good
mechanical conditions and that it adequately opens and closes.
7° - The installer must install the member for the manual release at a height inferior to
1,8 m.
8° - The installer will have to remove possible impediments to the motorized motion of
the door (eg. Door bolts, sliding bolts, door locks etc.)
9° - The installer will permanently have to put the tags warning against the deflection on
a very visible point or near possible fixed controls.
10° - The wiring harness of the different electric components external to the operator (for
example photoelectric cells, flashlights etc.) must be carried out according to the EN
60204-1.
11° - Keep the automatism controls (push-button panel, remote control etc.) out of the
children way. The controls must be placed at a minimum height of 1,5 m from the
ground and outside the range of the mobile parts.
12° - Before carrying out any installation, regulation or maintenance operation of the
system, take off the voltage by operating on the special magnetothermic switch
connected upstream.
13° - At the end of the installation, the installer will have to make sure that the parts of the
door do not encumber streets or public sidewalks.
14° - At the end of the installation, the installer will have to make sure that the
motion motor prevents or blocks the opening motion when the door is
loaded with a 20 kg weight, fixed in the middle of the inferior edge of the
door.
THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible damages caused
by the non observance during the installation of the safety standards and of the laws in
force at present.
3