ELECTRIC CONNECTIONS
B
BOSS SLAVE
WIRING CONNECTIONS BETWEEN MASTER AND SLAVE
MOTORS
SLAVE card allows users to operate a second motor on up-and-over doors with a
surface area exceeding 9 square metres.
Switch off the power supply to the system and insert the slave board into the J10
connector.
The board will be automatically configured once the system is switched back on
preset for 2 motors.
Connect the 4 wires (min. diam. 0,5 mm
Master control panel to the contacts 11-12-13-14 on the SLAVE control panel.
Connect the motor wires (min. diam. 1,5 mm
SLAVE control panel to the contacts - and + available in the box on the motor slave.
2
) from the contacts 11-12-13-14 of the
2
) from the contacts 17-18 of the
SLAVE CARD
code ACQ9087
8
7 6
5
4
3
14
13
BOSS MASTER
PEDESTRIAN SECURITY (terminals 5 ad 6)
In the event that the main up-and over-doors are also equipped with pedestrian
access, connect a microswitch (N.C. closed pedestrian access door) to signal to the
control panel that the pedestrian door is open or closed.
Connection should be carried out using terminals 5 and 6 (where no safety strips are
connected), or, where present, in safety strip contact series.
To ensure correct system operations, the DL3 LED lamp should be illuminated,
signalling that the pedestrian door is closed correctly.
If the led DL3 is OFF, the movement of the garage door will not be possible, because
the pedestrian door is open.
NOTE: Create a jumper if terminals 5 and 6 are not used by safety strips or other
devices.