Télécharger Imprimer la page

Faber Diamante Isola Instructions D'installation page 7

Masquer les pouces Voir aussi pour Diamante Isola:

Publicité

Les langues disponibles

Les langues disponibles

ATTACH THE SUPPORT
1. Put a thick, protective
covering over cooktop,
set-in range or countertop
to protect from damage
or dirt.
2. Determine and clearly
mark with a pencil on
.
t h e
c e i l i n g
w h e r e
the rangehood will be
installed.
3. A template (L in FIGURE
6) for mounting the support
is supplied in the carton
with the support. Use this
template to mark holes for
4. Determine and make necessary cuts for the ductwork. The duct
opening is shown on the mounting template (L in FIGURE 6). Install
ductwork before mounting the support.
5. If using the High Ceiling
Chimney Kit, remove
the CHIMNEY COVER
from the CHIMNEY
EXTENSION (A in
FIGURE 7). Position the
CHIMNEY EXTENSION
over the CHIMNEY
SUPPORT (B in FIGURE
7) so that the outside
edges and the electrical
holes line up. Attach the
CHIMNEY EXTENSION to
the CHIMNEY SUPPORT
using the 4 bolts (C in
FIGURE 7). Tighten bolts
securely.
6. Determine the proper location for the Power Supply Cable as
indicated on the template. Use a 1 1/4" Drill Bit to make this hole.
Run the Power Supply Cable. Use caulking to seal around the
hole. DO NOT turn on the power until installation is complete!
A knockout is provided at the top of the CHIMNEY SUPPORT (D
in FIGURE 8).
7. For ducted installations, place the round DAMPER (N in FIGURE
1) into the exhaust opening of the rangehood and press down.
FIGURE 8
8. Attach the CHIMNEY SUPPORT (D in FIGURE 8) to the ceiling.
Make sure that the support is firmly attached to the ceiling. Determine
the desired length of the support structure and adjust the length of the
support by removing the four screws (indicated in FIGURE 8) with a
flat head screwdriver. Once the length of the support is determined,
install and tighten the four screws.
Ductless installations require
a Ductless Conversion
Kit whose components are
pictured in FIGURE 9. Do
not use the DAMPER (N
in FIGURE 1) for ductless
installations. The LOWER
CHIMNEY COVER (B in
FIGURE 1) should be
discarded and replaced by
the new one with holes from
the Ductless Conversion Kit
(D in FIGURE 9).
FIGURE 6
As indicated in FIGURE
9, place the DUCTLESS
DIVERTER (A) over the
exhaust opening of the EASY
CUBE (E). Fit the DUCTLESS
DIVERTER EXTENSIONS
HORIZONTAL (B) into the
DIVERTER (A).
Remove the cover from the field wiring compartment. DO NOT
turn on the power until installation is complete! Connect
the Power Supply Cable to the rangehood. Attach the White
lead of the power supply to the White lead of the rangehood
with a twist-on type wire connector. Attach the Black lead of
the power supply to the Black lead of the rangehood with a
twist-on type wire connector. Connect the Green (Green and
Yellow) ground wire under the Green grounding screw.
FIGURE 7
1. The UPPER CHIMNEY
COVER (C in FIGURE 10)
attaches using two screws
provided (G in FIGURE 10).
If using the High Ceiling
Chimney Kit, use the
UPPER CHIMNEY COVER
supplied with the kit. Slide
up and attach the UPPER
CHIMNEY COVER.
2. Attach the duct work to
the DAMPER (N in FIGURE
1). Make sure to seal all
joints with duct tape to
prevent leaks.
3. The LOWER CHIMNEY
COVER (B in FIGURE
10) attaches using two
screws provided (G in
FIGURE 10). Install the
LOWER CHIMNEY COVER
by sliding it up over the
support and the UPPER
CHIMNEY COVER.
For ductless installations, line up the DUCTLESS DIVERTER
EXTENSIONS HORIZONTAL (B in FIGURE 9) with the holes
in the LOWER CHIMNEY COVER (D in FIGURE 9) and snap
in the VENT GRIDS (C in FIGURE 9).
FOR DUCTLESS INSTALLATIONS
MAKE THE ELECTRICAL CONNECTION
INSTALLING THE RANGEHOOD
FIGURE 9
FIGURE 10
Version 08/06 - Page 7