This rangehood can be installed as either ducted or ductless. When installed ductless, the rangehood vents out of a grate on
the back of the lower chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL BE
USED AND CAREFULLY CALCULATE ALL MEASUREMENTS.
(vented to the outside)
The Diamante Isola chimney is highly
adjustable and designed to meet varying
ceiling heights as indicated in FIGURE 4.
The chimney can be adjusted for ceilings
between 7' 5 9/16" and 9' 3/16" depending
on the distance between the bottom of
the hood and the cooktop (distance x in
FIGURE 4).
For higher ceiling installations, the High
Ceiling Chimney Kit includes an additional
support structure which adds 27 1/2" to the
ceiling heights in FIGURE 4.
PLAN THE INSTALLATION
DUCTED
INSTALLATION DIMENSIONS
upper
chimney
cover
lower
chimney
cover
canopy
x = distance from hood to cooktop
(varies depending on installation)
min - 24", suggested max - 30"
also consult cooktop
manufacturer's recommendation
cabinet base
2
min
3/4"
15
max
3/8"
23
5/8"
3
3/16"
min & max ceiling height examples
x = 24"
x = 26"
min
min
x
7'
7'
5 9/16"
7 9/16"
max
max
8'
8'
8'
6 3/16"
8 3/16"
36"
WARNING
D U E T O T H E S I Z E
AND WEIGHT OF THIS
R A N G E H O O D ,
SUPPORT MUST BE
FIRMLY ATTACHED TO
THE CEILING. For plaster
or sheet rock ceilings, the
support must be attached
to the joists.
not possible, a support
structure must be built
behind the plaster or sheet
rock. The manufacturer
assumes no responsibility
for injury or damage caused
by improper installations.
FIGURE 4
DUCTED
DIMENSIONS
x = 28"
x = 30"
min
min
7'
7'
9 9/16"
11 9/16"
max
max
9'
10 3/16"
3/16"
!