READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. b)
Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper-
corn Beef Flambé). c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. d)
Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING: SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - You may be burned. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result. Use an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and
you already know how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire department
is being called. 4. You can fight the fire with your back to an exit.
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop.
This minimum clearance may be higher depending on local building code. For example, for gas ranges, a minimum of 30" may
be required. The maximum depth of overhead cabinets is 13". Overhead cabinets on both sides of this unit must be a minimum
of 18" above the cooking surface or countertop. Consult the cooktop or range installation instructions given by the manufacturer
before making any cutouts. MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured
Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280). Four wire power supply must be used and the appliance wiring must be revised. See Electrical
Requirements.
AVERTISSEMENT - POUR MINIMISER LE RISQUE DʼUN FEU DE GRAISSE SUR LA TABLE DE CUISSON : a) Ne jamais laisser
un élément de la table de cuisson fonctionner sans surveillance à la puissance de chauffage maximale; un renversement/
débordement de matière graisseuse pourrait provoquer une inflammation et le génération de fumée. Utiliser toujours une
puissance de chauffage moyenne ou basse pour le chauffage dʼhuile. b) Veiller à toujours faire fonctionner le ventilateur
de la hotte lors dʼune cuisson avec une puissance de chauffage élevée ou lors de la cuisson dʼun mets à flamber (i.e.
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Nettoyer fréquemment les ventilateurs dʼextraction. Veiller
à ne pas laisser de la graisse sʼaccumuler sur les surfaces du ventilateur ou des filtres. d) Utiliser toujours un ustensile
de taille appropriée. Utiliser toujours un ustensile de taille adapté à la taille de lʼélément chauffant.
AVERTISSEMENT: - POUR PRÉVENIR LES BLESSURES EN CAS DE FEU SUIVRE LES RECOMMANDATIONS SUIVANTES:
ÉTOUFFEZ LE FEU avec un couvercle métallique et fermez le brûleur. Si le feu ne s'éteint pas tout de suite, QUITTEZ
LES LIEUX ET APPELEZ LES POMPIERS. NE TOUCHEZ JAMAIS UNE CASSEROLE EN FLAMMES. N'UTILISEZ JAMAIS
DE L'EAU ou un torchon mouillé pour éteindre le feu - ce qui pourrait causer une explosion de vapeur. N'utilisez un
extincteur que si: 1. Vous avez un modèle ABC et vous connaissez bien son mode d'emploi. 2. Le feu est petit et peu
répandu. 3. Les pompiers sont déjà prévenus. 4. Vous avez une sortie derrière vous.
TOUTE OUVERTURE DANS LE MUR OU LE PLANCHER À PROXIMITÉ DE LA HOTTE DOIT ÊTRE SCELLÉ
Gardez 24 po. de hauteur entre le bas de la hotte et la surface de cuisson. Cette hauteur minimum peut être plus haute suivant le
code municipal. Par exemple, les cuisinières à gaz peuvent requérir 30 po. de hauteur. Les armoires au-dessus ne dépasseront
pas 13 po. de profondeur. Les armoires au-dessus de chaque côté devront être au moins à 18 po. au-dessus de la surface
de cuisson. Consultez la fiche technique avant de découper les armoires. L'installation de cette hotte doit être conforme aux
Réglements de Manufactured Home Construction and Safety Standards, titre 24 CFR, Section 3280 (anciennement Federal
Standard for Mobile Home Construction and Safety Standards, titre 24 CFR, Section 3280 (anciennement Federal Standard for
Mobile Home Construction and Safety, titre 24, HUD, Section 280). Le branchement électrique se fait avec une raccordement à
4 fils. Consultez la fiche technique électrique.
LISEZ BIEN CETTE FICHE AVANT D'INSTALLER LA HOTTE
ISOLA
Island Mount Canopy Rangehood
• Installation Instructions
• Use and Care Information
READ AND SAVE THESE INSTRUCTIONS
The Installer must leave these instructions with the homeowner.
The homeowner must keep these instructions for future reference
and for local electrical inspectors' use.
Version 09/05 - Page 1

Publicité

Table des Matières
loading

Sommaire des Matières pour Faber ISOLA

  • Page 1 ISOLA Island Mount Canopy Rangehood • Installation Instructions • Use and Care Information READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future reference and for local electrical inspectors' use.
  • Page 2: Venting Requirements

    VENTING REQUIREMENTS This appliance should be connected directly to the fused Determine which venting method is best for your application. disconnect (or circuit breaker) through flexible, armored or Ductwork can extend either through the wall or the roof. nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever nec- The length of the ductwork and the number of elbows should essary.
  • Page 3 RÈGLEMENTS D'ÉVACUATION Confirmer la sortie d'évacuation - soit par le mur, soit par A utiliser avec un dispositif de reglage de vitesse a semi- le toit. conducteurs. Utilisez une longueur de tuyauterie minimale avec les moindres AVERTISSEMENT – POUR MINIMISER LES RISQUES de coudes pour la plus grande efficacité.
  • Page 4: Plan The Installation

    • Measuring Tape or Ruler • Level The Isola chimney is adjustable and designed to meet varying ceiling heights as • Pencil indicated in FIGURE 1. The chimney can be adjusted for ceilings between 7' 10 •...
  • Page 5: Install The Rangehood

    WARNING DUE TO THE SIZE AND WEIGHT OF THIS RANGEHOOD, THE SUPPORT MUST BE FIRMLY ATTACHED TO THE CEILING. For plaster or sheet rock ceilings, the support must be attached to the joists. If this is not possible, a support structure must be built behind the plaster or sheet rock.
  • Page 6 For ductless installations: Ductless installations require a Ductless Conversion Kit. This kit consists of two lower chimney covers with holes for the exhaust air, a ductless diverter, two grids to cover the holes in the chimney cover, two charcoal filters. The ductless diverter must be installed before the lower chimney covers are attached as in FIGURE 9.
  • Page 7: Warranty & Service

    FIGURE 16 WARRANTY & SERVICE All Faber products are warranteed against any defect in ma- terials or workmanship for the original purchaser for a period of 1 year from the date of original purchase. This warranty covers labor and replacement parts. The warranty does not cover consumable parts such as filters and light bulbs.
  • Page 8: Outils Nécessaires À Lʼinstallation

    • Crayon • Outil à calfeutrage La cheminée Isola est réglable pour différentes hauteurs de plafond, entre 7 pi 10 7/8 po • Ruban à conduit and 9 pi 3 po (regardez la distance entre la hotte et la table de cuisson - X en FIGURE 1.
  • Page 9: Installation Du Support

    AVERTISSEMENT À CAUSE DE LA DIMENSION ET DU POIDS DE CETTE HOTTE, LE SUPPORT DOIT ÊTRE FIXÉ FERMEMENT AU PLAFOND. Pour les plafonds en plâtre ou en panneaux muraux secs, le support doit être fixé aux solives. Si cela est impossible, une structure renforcée doit être érigée derrière le plâtre ou des panneaux muraux secs.
  • Page 10 Pour installation sans conduit : Les installations sans conduit requièrent le nécessaire sans conduit. ( ACCESSOIRES POUR LʼINSTALLATION page 8) nécessaire comprend deux couvercles de cheminée inférieure avec trous dʼéchappement dʼair, un déflecteur sans conduit, deux grilles pour couvrir les trous du couvercle de cheminée et deux filtres au charbon.
  • Page 11: Utilisation Et Entretien

    GARANTIE ET SERVICE Faber garantit à lʼutilisateur-acheteur dʼorigine que les produits Faber vendus neufs par nous sont sans vice de matériel et de main-dʼoeuvre dʼorigine pour une période dʼun an à partir de la date dʼachat. La garantie couvre la main-dʼoeuvre et les pièces de remplacement.
  • Page 12: Diagrammes De Filage Ventilateur Interne Standard

    DIAGRAMMES DE FILAGE VENTILATEUR INTERNE STANDARD *VENTILATEUR À DISTANCE DISPONIBLE •Cette hotte utilise des ampoules halogènes de 20 W. * Si on utilese un ventilateur à distance avec cette hotte, l'ampérage ne doit excéder 4 ampères. Version 09/05 - Page 12...

Table des Matières