Leveling Foot Locations
10. Level and Secure the Bath
All Installations
IMPORTANT! Do not anchor the bath to the stud pocket until instructed to do so.
IMPORTANT! Do not level the bath with the counterweights installed. The counterweights and door
assembly could cause the bath to shift, causing leveling to be incorrect.
Install metal shims under each of the leveling feet to protect the floor.
Check for level on the back edge and each side of the bath as shown.
Adjust the leveling feet as needed to level the bath.
Recheck for level.
Repeat until the bath is level.
Check each of the leveling feet and confirm they make firm contact with the metal shims and
subfloor.
Secure the bath to the studs with nails or screws, using the nailing-in flange.
1128532-2-G
All manuals and user guides at all-guides.com
Nail furring strips
to the studs.
Bottom View
20
Stud
Use #6 large-head
galvanized nails to
secure the nailing-in
flange to the studs.
Leveling Foot Locations
Drill a small hole
through the nailing-in
flange at each stud.
Kohler Co.