NI-UN
5.3. AND function for inputs
5.4. Anti-opening and anti-tear Tamper
5.5. Meaning of LED
20
Using the SW6 switch, you can choose how the smoke bomb is activated according
to the following table:
The smoke generator is activated only if the smoke input with
ON
an alarmed siren (AND function) is alarmed.
SW-6
The smoke generator is activated immediately when the
OFF
smoke input is alarmed
The anti-opening and anti-tear tamper refer to a single OUT TAMP output with
mass reference in the closed container position.
Tear control can be enabled/disabled using the SW5 switch as per table:
ON
Enabled
SW-5
OFF
Disabled
The activity and status of the device are highlighted by a multicolored led at
the bottom of the body and by the status of the outputs "EXHAUST SMOKE
GENERATOR" and "ERROR".
According to the following sequential scheme, the system status information is
shown every 6 seconds. The LED is turned on for a short time at 1.5" intervals
showing with the applied color, the state of the device.
The 3 consecutive flashes referring to the second "0", can take on 4 color variants
and are to indicate the state of the smoke generator. This indication is repeated
every 6 seconds.
Green
Regular smoke generator perfectly functioning
Red
Out-of-stock smoke generator (already used)
Yellow
Faulty smoke generator
Communication error with the smoke generator activation
Purple
circuit (probable lack of electrical connection or smoke
generator absence)
Installer manual
Device programming