3. Data sheets
Smoke and siren impedance entry: ~4kΩ
Out of the smoke generator outputs and
Tamper and anti tear output: N.C (reported contact a GND) Anti-tear that can be
Sound power piezoelectric siren: > 95 dB at 1 m.
Average duration of smoking: From 30 to 45 sec.
Recommended height for mounting: From 2, 1 0 to 2,30m above the ground
Smoke generator replacement: Recommended every 3 years
Degree of container protection: IP 30
16
Power From 3,0 Vcc to 15,0 Vcc
Absorption 3,000V÷7,999V: ~180μA
Positive power to start: > 3Vcc a max. 15 Vcc
Minimum activation time: 1 sec. (Input Start Smoking, Input Start Siren)
error:
Always supervision of: Valid smoke generator, faulty smoke generator,
Saturable Volume: 100 m
Signalling LED: 2 Red LEDs for variation Status Inputs + 1 Red /
Operating temperature: 0°C ÷ +45°C
Storage temperature: -20°C ÷ +55°C
Size and weight: 175x120x95 mm, 800g smoke generator included
ATTENTION!
During the container closure and smoke generator
enablement phase, the current absorption increases considerably for
the energy accumulation required for the start of the smoke bomb. The
energy storage time can range from 5 seconds with an energy source
capable of delivering 1A, to 30 seconds with an energy source capable of
delivering 100 mA (e.g. a lithium battery of 3.6V mod. 14500).
8,000V÷15,000V: ~220μA
(with LEDs disabled)
N.C (open collector with reference to GND current
max. 100 mA.)
disabled with J2 jumper
spent smoke generator, smoke generator activation
circuit present.
3
green LED for radio communication
Installer manual
Data sheets