en-us Electrical connection
4.2 Securing the cooktop to the countertop
The cooktop must be secured from below using the hold-
down brackets provided, so it does not slip.
Place the cooktop face down on a soft underground.
1.
Attach the hold-down brackets to the underside of the
2.
cooktop with the provided short screws
tighten the screws.
Rotate the hold-down brackets so that the appliance
3.
can be placed in the cutout.
4.
CAUTION Do not let the cooktop drop into place.
Make sure that the cooktop is supported along the
▶
edges when carefully placing it into the cutout.
Turn the cooktop over and place it carefully into the
countertop cutout.
Insert the clamping screws into the hold-down bracket
5.
and secure the cooktop to the countertop
delicate countertops by placing a wooden disk under-
neath.
Tighten the hold-down bracket screws on the cooktop
6.
underside.
Power supply
All models must be connected with the included 39" (1 m) flexible conduit.
Models
CIT304YB
CIT304YM
CIT365YB
CIT367YG
CIT367YGS
CIT367YM
CIT367YMS
5.2 Connecting electrical supply
WARNING
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
▶
ON accidentally.
8
5 Electrical connection
Electrical connection
Read these instructions to safely connect your appliance
Electrical connection
to the electrical supply.
5.1 Electrical requirements
. Do not
Ensure that the following general requirements are met.
You can find the rating plate with the electrical specifi-
¡
cations on the underside of the appliance.
→ "Rating plate location", Page 9
The junction box must be located within 3 feet of the
¡
cooktop connection. It should be easily accessible for
service purposes.
. Protect
240 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
30 A
30 A
50 A
50 A
50 A
50 A
50 A
Note: If the cooktop is installed and connected as speci-
fied here, it will be grounded in compliance with the Na-
tional Electrical Code.
Install a suitable junction box (not furnished).
1.
The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the requirements
of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
max. 2¾" (69 mm) + fitting/conduit 1" (25 mm)
min. 1" (25 mm) air clearance
approx. 12" (300 mm)
junction box
flexible conduit approx. 3 ft. (900 mm)
208 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
30 A
30 A
50 A
50 A
50 A
50 A
50 A