LIGHTING SYSTEM WITH FLUORESCENT TUBES
This appliance is provided with a device for the tank lighting circuit , formed by
ballasts and security electronic starters
The security electronic starter (placed in the motor space):
-disconnects the circuit after 60" if the tubes doesn' t start to light;
-avoids the danger of a short-circuit disconnecting automatically the tubes.
If a tube does not light press the button on the starter: if tube is defective or exhaust,
it will come up again. Then replace the tube and press the button again.
In case of defective starter it is necessary to replace it with an equal or electrically
similar one.

MALFUNCTIONS AND REMEDIES

Most of the functioning inconveniences are generally due to defective electrical connections. These
problems can usually be solved on the place.
The unit does not start:
-check that there is voltage at the wall socket;
-check that the unit is properly plugged.
-check the fuse continuity (if present)
The internal temperature is not cold enough:
-check that the unit is not placed too close to any heating source;
-check that there is not too much ice on the evaporator, or on the evaporating shelves;
-check the temperature setting;
-check that the condenser is not blocked by dirt;
-check that behind the cabinet air can properly circulate;
-check the perfect closing of the glass door; the
with a device that, during door-open time, switch off automatically the internal motor-fan.
The unit is noisy:
-check that all the bolts and nuts are properly fasten;
-check that the unit is placed on an even surface;
-check if any pipe or fan is in contact with any other part of the body.
INFORMATIONS ABOUT SERVICE
models with ventilated refrigeration are equipped