Télécharger Imprimer la page

Minebea Intec PR 6130/65S Manuel D'installation page 54

Publicité

Les langues disponibles

Les langues disponibles

Hazardous area Zone 0
Load cell
#1 ... #8
Output parameters:
Ex ia
Intrinsically safe circuit in
type of protection Ex ia
The output parameters are
given by the connected
evaluation unit.
Hazardous area Zone 1
Load cell
#1 ... #8
Output parameters:
Ex ia or
Intrinsically safe circuit in
Ex ib
type of protection Ex ia
or Ex ib. The output
parameters are given by
the connected evaluation
unit.
Hazardous area Zone 20
Load cell
#1 ... #8
Output parameters:
Ex ia
Intrinsically safe circuit in
type of protection Ex ia.
The output parameters are
given by the connected
evaluation unit.
Hazardous area Zone 21
Load cell
#1 ... #8
Output parameters:
Ex ia or
Intrinsically safe circuit in
Ex ib
type of protection Ex ia or
Ex ib. The output
parameters are given by
the connected evaluation
unit.
Datum
Name
Date
Erstellt
14.11.18
Schallhorn
Written by
Geprüft
15.11.18
Hiller
Reviewed by
Freigabe
15.11.18
Schallhorn
Released by
Cable junction box
Ex ia IIC T6/T4 Ga
-20°C ≤ Ta ≤ 40°C/60°C
Cable junction box
Ex ia IIC T6/T4 Ga
-20°C ≤ Ta ≤ 40°C/60°C
Cable junction box
Ex ia IIIC T90°C Da
-20°C ≤ Ta ≤ 40°C/60°C
Cable junction box
Ex ia IIIC T90°C Da
-20°C ≤ Ta ≤ 40°C/60°C
Material
.
Ausgabe / Revision
Änderung / Alteration
01
PA50181104
Input parameters:
Intrinsically safe circuit in type
of protection Ex ia
Ui = 25V Pi = any
Ci = 0nF Li = 0mH
Ii
Ta
Temp. class
210mA
40°C
T6
325mA
60°C
T4
370mA
40°C
T4
Input parameters:
Intrinsically safe circuit in type
of protection Ex ia or Ex ib
Ui = 25V Pi = any
Ci = 0nF Li = 0mH
Ii
Ta
Temp. class
210mA
40°C
T6
325mA
60°C
T4
370mA
40°C
T4
Input parameters:
Intrinsically safe circuit in type
of protection Ex ia
Ui = 25V Pi = any
Ci = 0nF Li = 0mH
Ii
Ta
325mA
60°C
370mA
40°C
Input parameters:
Intrinsically safe circuit in type
of protection Ex ia or Ex ib
Ui = 25V Pi = any
Ci = 0nF Li = 0mH
Ii
Ta
325mA
60°C
370mA
40°C
Benennung / Title
Safety Instructions
Zeichnungs-Nr. / Drawing number
36931-751-16
Evalaution unit
with Ex ia output
circuit to the load
cells
Evalaution unit
with Ex ia or Ex ib
output circuit to
the load cells
Evalaution unit
with Ex ia output
circuit to the load
cells
Evalaution unit
with Ex ia or Ex ib
output circuit to
the load cells
Maßstab /
Scale
1:1
Blatt
2
Sheet
von
3
of

Publicité