Télécharger Imprimer la page

Minebea Intec PR 6130/65S Manuel D'installation page 47

Publicité

Les langues disponibles

Les langues disponibles

10.
Equipment Ratings:
Intrinsically safe for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G hazardous (classified)
locations; Intrinsically safe for Class I, Zone 0, Group IIC hazardous (classified) locations; Intrinsically safe
for Zone 20, Group IIIC hazardous (classified) locations; nonincendive for Class I, Division 2, Groups A, B,
C, and D, hazardous (classified) locations; Suitable for Class II and III, Division 2 hazardous (classified)
locations. Temperature classification T4. Ambient temperature range -20°C to +60°C for PR 6130/6ab and
PR 6021/68S,-30°C to +60°C for PR6130/64Sa-Temp, PR6130/64C-Temp and PR6130/65S-Temp and -
40°C to 60°C for PR6130/68S-Temp and PR6021/68S-Temp. Indoor and outdoor Type 4X and IP6x.
11.
The marking of the equipment shall include:
PR 6130/6[a][b] and PR 6021/68S Cable Junction Box
IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G T4 - 36931-751-07; 4X, IP6x
NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G T4; 4X, IP6x
S CL II, DIV 2, GP E,F,G / T4; 4X, IP6X,
S CL III, DIV 1 T4 - 36931-751-07; 4X, IP6x
CL I, Zone 0, AEx ia IIC T4 - 36931-751-07; 4X, IP6x
Zone 20, AEx ia IIIC T90°C - 36931-751-07; 4X, IP6x
T4 Ta= -20°C to 60°C
PR 6130/64Sa-Temp, PR 6130/64C-Temp and PR 6130/65S-Temp Cable Junction Box
IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G T4 - 36931-731-07; 4X, IP6x
NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G T4; 4X, IP6x
S CL II, DIV 2, GP E,F,G / T4; 4X, IP6X,
S CL III, DIV 1 T4 - 36931-751-07; 4X, IP6x
CL I, Zone 0, AEx ia IIC T4 - 36931-731-07; 4X, IP6x
Zone 20, AEx ia IIIC T90°C - 36931-731-07; 4X, IP6x
T4 Ta= -30°C to 60°C
PR 6130/68S-Temp and PR 6021/68S-Temp Cable Junction Box
IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G T4 - 36931-721-07; 4X, IP6x
NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G T4; 4X, IP6x
S CL II, DIV 2, GP E,F,G / T4; 4X, IP6X,
S CL III, DIV 1 T4 - 36931-721-07; 4X, IP6x
CL I, Zone 0, Ex ia IIC T4 - 36931-721-07; 4X, IP6x
Zone 20, AEx ia IIIC T90°C - 36931-721-07; 4X, IP6x
T4 Ta= -40°C to 60°C
12.
Description of Equipment:
General - The Cable Junction Boxes are designed to interconnect up to 8 load cells and then connect this
arrangement to the interface of an evaluation unit (e.g. indicator).
Construction - The Cable Junction Boxes series PR 6130/6... and PR 6021/6... consist of stainless steel
housings with ingress protection IP6x in accordance with ANSI/IEC 60529 and Type 4X. All screws, flat and lock
washers are also made of stainless steel.
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals LLC. 1151 Boston-Providence Turnpike, Norwood, MA 02062 USA
T: +1 (1) 781 762 4300 F: +1 (1) 781 762 9375 E-mail:
F 347 (Mar 16)
SCHEDULE
US Certificate Of Conformity No: FM17US0275X
information@fmapprovals.com www.fmapprovals.com
Page 2 of 4

Publicité

loading